![axing MIE 4-02 Operation Instructions Manual Download Page 87](http://html1.mh-extra.com/html/axing/mie-4-02/mie-4-02_operation-instructions-manual_3036607087.webp)
Operation instructions | MIE 4-02 | MIE 8-02
26
2020-11-13 | Technical improvements, changes in design, printing- and other errors expected.
Re-mapping PIDs by hand
If packets should get a very specific OUT PID, this can be entered manually.
Click in the OUT PID column of the program.
Enter the PID with the keyboard or increase/decrease the PID with the arrow keys.
Click on the green check mark.
This will complete the entry first.
Click SAVE CHANGES.
The entered PIDs are saved in the headend.
3.4.6.
Duplicating a program
Programs can be duplicated in phase 2. This allows, for example, to offer a program in two different languages
at the output (arte DE/arte FR).
Click on the program to be duplicated.
The table with the program information and contents opens.
Click on
Add
.
The program is duplicated 1:1. It has the same name and the same input stream ID. It is not yet assigned
to any modulator.
Assign the duplicated program to a different modulator than the modulator of the original program. The
original and duplicated programs can now be configured differently.