axing EoC 1-01 Ethernet over Coax Operation Instructions Manual Download Page 3

 

2015-01-01 | © AXING AG Schweiz | Konstrukions -, Typenänderung, Irrtümer und Druckfehler vorbehalten 

Safety instructions 

 

Do NOT use the device near water or in rooms with high humidity such as humid cellars or near swimming 

pools. 

 

Do NOT use the device outdoors. All connections must be located inside a building.  

 

Keep the device away from moisture, dust or corrosive liquids. 

 

Do NOT install the device, use it or perform maintenance during a thunderstorm. There is a risk of electric 

shock during thunderstorm. 

 

Connect ONLY appropriate accessories to the device. 

 

Make sure that all cables are connected to the correct port. 

 

Carefully lay the Ethernet, antenna and electric cables to ensure that nobody can step on or stumble over 

them. 

 

Do NOT cover the ventilation slots of the device since insufficient air supply may result in damage to the 

device. 

 

Do NOT place any objects on the device. Position the device in a place where NOBODY can step on it. 

 

Prior to maintenance or dismounting work, disconnect the Ethernet and electric cable from the device. 

 

In case of damage, interrupt the power supply. 

 

Do NOT try to repair the device. Contact your local retailer to order a new device. 

 

Do NOT open the device or unit. Opening the device or removing its covers causes risks, for example due 

to high voltage. This device should ONLY be repaired or uninstalled by qualified service personnel. For 

more information, contact your retailer. 

 

Summary of Contents for EoC 1-01 Ethernet over Coax

Page 1: ...EoC 1 01 Ethernet over Coax Operation Instructions...

Page 2: ...cope of delivery 4 1 3 Field of application 5 1 4 Connections indications operating elements 6 1 5 Application examples 7 2 Installation and commissioning 9 3 Basic functions 10 3 1 Standby mode 10 3...

Page 3: ...ct port Carefully lay the Ethernet antenna and electric cables to ensure that nobody can step on or stumble over them Do NOT cover the ventilation slots of the device since insufficient air supply may...

Page 4: ...omponents must be disposed of separately 1 2 Scope of delivery EoC 1 01 1 x EoC 1 01 Ethernet over Coax Modem 1 x Network cable 1 5 m RJ45 1 x Power cable with euro plug 1 x CFA 8 00 terminating resis...

Page 5: ...can be realized The feeding in is performed via the return channel capable terrestrial input of the SAT multiswitch via the terrestrial input of the antenna distributor structure or via a return chan...

Page 6: ...85 862 MHz 5 Reset button 6 Security button 7 LAN 1 RJ 45 socket 8 Mains socket 110 230 V 9 Power LED 10 EoC LED 11 LAN 1 LED 12 LAN 2 LED A TV or radio device can be connected to the TV F socket on t...

Page 7: ...ing in of IP data in a SAT IF distribution structure Example 1 The feeding of the IP signal is performed via the return channel capable antenna socket Example 2 The feeding of the IP signal is perform...

Page 8: ...le 4 IP data feeding for exactly one antenna socket The feeding of the IP signal is performed via the EoC combiner TZU 40 03 The integrated high pass of 85 1006 MHz prevents the transmission of the IP...

Page 9: ...distribution structure see example 2 or 4 3 Connect your computer using the enclosed Ethernet cable to one of both RJ 45 LAN sockets of the second EoC modem 4 Then connect the EoC modem using the EoC...

Page 10: ...raffic WiFi LED green if WiFi is switched on green flashing in case of data traffic 3 1 Standby mode The EoC modem switches after several minutes without data traffic to the Standby mode The Power LED...

Page 11: ...ity button on the rear side of the EoC device for 5 8 seconds until the Power LED flashes Carry out this step for all devices Pair and group formation Press the security button briefly 1 s on the rear...

Page 12: ...utton on each EoC modem for 10 seconds to restore the factory settings of the EoC modem If necessary generate a new network key see chapter 4 on page 12 EoC LED off is not lit The EoC devices cannot b...

Page 13: ...Mbps Range up to 700 m Modulation 4096 1024 256 64 16 8 QAM QPSK BPSK and ROBO modulation scheme Encryption 128 bit AES Ethernet interface 10 100 1000 Mbps Network standards Home Plug AV IEEE1901 IEE...

Page 14: ...Operation Instructions EoC 1 01 Ethernet over Coax 14 2015 01 01 AXING AG Schweiz Konstrukions Typen nderung Irrt mer und Druckfehler vorbehalten 6 2 Drilling template 41 90...

Page 15: ...2015 01 01 AXING AG Schweiz Konstrukions Typen nderung Irrt mer und Druckfehler vorbehalten 15...

Page 16: ...Operation Instructions EoC 1 01 Ethernet over Coax 16 2015 01 01 AXING AG Schweiz Konstrukions Typen nderung Irrt mer und Druckfehler vorbehalten...

Reviews: