![axing EoC 1-01 Ethernet over Coax Operation Instructions Manual Download Page 10](http://html1.mh-extra.com/html/axing/eoc-1-01-ethernet-over-coax/eoc-1-01-ethernet-over-coax_operation-instructions-manual_3036670010.webp)
Operation Instructions | EoC 1-01 | Ethernet over Coax
10
2015-01-01 | © AXING AG Schweiz | Konstrukions -, Typenänderung, Irrtümer und Druckfehler vorbehalten
3.
Basic functions
After having switched on the EoC modem, the LEDs should indicate the following states:
The green Power LED is lit.
–
After approx. 10 seconds, the LEDs are lit/flashing as follows:
–
EoC LED green (flashes in case of data traffic)
–
LAN LED green (flashes in case of data traffic)
–
WiFi LED green (if WiFi is switched on) green (flashing in case of data traffic)
3.1.
Standby mode:
The EoC modem switches after several minutes without data traffic to the Standby mode. The Power LED is
flashing green then.
3.2.
EoC Reset button:
The EoC reset button is used for the following functions:
reset to the factory default setting (press > 10 s).
delete the network key (press 5…8 s)
generate a private network (press <1 s)
3.3.
EoC Reset Function:
Hold the reset button depressed for one second using a bent up paper clip, in order to reset the device to the
factory defaults.
The EoC reset button does not work in standby mode.