3: I
n De
pt
h/
A
dv
an
ce
d P
ro
gr
am
m
in
g •
2
0
The xSelector Home Page
The home page simply acts as a “jumping off” point to access the configuration pages. The home page contains
the following information:
Fig. 3-1: xSelector Home page
•
Node ID
(shown if ID assigned): xSelector can be assigned an ID number which is used to assist with
Simple Setup IP addressing and channel numbering.
•
Software Version:
The software version currently running on the xSelector.
•
Temperature:
The temperature reading of the internal sensor. Alarm status will appear if the temperature is
above acceptable limits.
• Sync:
A solid SYNC indication represents synchronization with the network clock-sync source. Under the
SYNC indication, a calculated ID value of the master clock is displayed; the IP address or MAC value of
the source of clock (depending on software version).
»
After the address is a
p#
indication, showing the priority setting of the master. The numbers that fol-
low are health indicators of the sync.
»
The lower-case Delta indicates phase error between local time and recovered clock.
»
The lower-case Sigma indicates variations in the delta. The values of delta and sigma are expected to
be below +/- 1.0 micro seconds.
»
Frequency Adjustment indicates adjustments made to local clock in order to match recovered net-
work time. Accepted value is to be /- 5.0 ppm.
Summary of Contents for xSelector
Page 6: ......
Page 8: ...CAT 6 small and light yet sound and data pour forth What magic is this...
Page 18: ...Do digital streams dream of electric DJs Just Bradbury knows...
Page 26: ...To and fro bits flow Audio anywhere now Fingertips decide...
Page 52: ...Elvis Costello was a true visionary Kesha not so much...