VII -Cycle optimization
Axess Sepro User Manual
V2.0 |->
DD0000116802
23
13.2.06
VII - CYCLE OPTIMIZATION
VII - 1.Introduction
The cycle is optimized using the cycle parameters. The changes are only carried out in the cycle
running. The changes are saved and therefore retained when you change program.
There are 5 types of cycle parameters:
Note:
The procedure for changing these parameters is the same whatever mode is selected, apart
from one particularity in manual mode: see “Teaching the points in manual”, page 13.
Type of cycle parameter
Function
Use
Mode advised
for
optimization
Points
For changing the destination of a numeric
axis, either by entering a position from the
keyboard, or by teaching it.
Speeds
For changing the movement speed of the
numeric axes.
Time delays
For changing the wait time between 2 actions
or an output’s activation time.
Tolerances
For changing the tolerance from which it is
possible to order the following action even if
the current movement hasn’t finished.
Note:
The tolerance is only taken into account in
automatic mode when speed Kv >= 80%.
Stacking and counters
For changing the gaps between releases or the
value of the counters CNT.
For changing the stacking structure or the
value of the stacking counters CNT-Stk.