2.

Siren duration

Configuration LED 2 is lit up.

1 sec. to 60 min., factory set to 30 sec.

3.

Alarm bypass

Configuration LED 2 and 3 are lit.

1 sec. to 5 min., factory set to 30 sec

4.

Siren volume

Configuration LED 1 is lit.

1 to 99 (65-90 dB/m), 0 turns off the siren. Factory set to 50.

5.

Signal volume

Configuration LED 1 and 3 are lit.

1 to 99 (45-77 dB/m), 0 turns of signal. Factory set to 50.

When the settings are made, press

P1 until two lines are shown in the display and

all three configuration LEDs are flashing. Therafter, press and hold

P1 until six lines

are shown in the display and all configuration LEDs turn off.

6 (17)

Manual UDR Plus

Summary of Contents for UDR-Plus

Page 1: ...Axema Access Control AB Box 90215 120 23 Stockholm Sweden 08 722 34 40 info axema se www axema se UDR Plus Universal door alarm Manual Updated 2018 11 17...

Page 2: ...lation examples 7 The alarm is set of by a closing magnet contact and is reset when the door is shut 8 NC relay when the door is closed 8 NO relay when the door is closed 9 UDR plus with code lock and...

Page 3: ...an signal when a valid pass is made optional function and activates the internal siren when an invalid pass is made The functions are programmed using a DIP switches and duration times are programmed...

Page 4: ...d reset the alarm if the door is closed 7 8 Signal Activates signal 45 77 dB and flash 0 deactivates sound sig nal Follows the status of the input no duration control 9 10 Supply voltage 10 30 V DC 9...

Page 5: ...activated The red dot by the display indicates that the delay is in minutes l A short press on P1 moves to the next setting l A long press on P1 until Status LED 13 changes switches the function of P2...

Page 6: ...1 to 99 65 90 dB m 0 turns off the siren Factory set to 50 5 Signal volume Configuration LED 1 and 3 are lit 1 to 99 45 77 dB m 0 turns of signal Factory set to 50 When the settings are made press P1...

Page 7: ...Installation examples 7 17 Manual UDR Plus...

Page 8: ...alarm should not reset connect terminal 3 to C2 and NC6 The alarm has to be reset manually using the reset input l Duration of siren and any delay has to be set See Programming NC relay when the door...

Page 9: ...NO relay when the door is closed Terminal on UDR Plus Connects to 1 NO on magnet contact 2 C on magnet contact 3 NC on magnet contact 9 10 30 VDC 10 GND 9 17 Manual UDR Plus...

Page 10: ...alarm has not been activated UDR is reset when the door is shut if switching magnetic contact is used If the alarm has been activated it has to be reset using code l If the alarm is set of while the...

Page 11: ...1 NO on magnet contact 2 C on magnet contact 3 Terminal 15 on UDR Plus 5 NO on code lock 6 C on code lock 9 10 30 VDC 10 GND Also connects to electric lock 11 Electric lock 13 10 30 VDC 16 NC on magn...

Page 12: ...larm is reset when a valid pass is made l The lock is connected to UDR l If B16 or 17 is used connect the door monitoring directly to UDR Plus according to the top example Terminal on the door control...

Page 13: ...Terminal on UDR Plus 11 Electric lock 13 17 Manual UDR Plus...

Page 14: ...nvalid pass is made After the door has been closed the flash continues for the set siren duration l Reset by connecting terminal 5 and 6 1 Alarm trigger 0 sec cannot be changed 2 Siren duration 1 sec...

Page 15: ...Terminal on UDR Plus Connects to 1 C on magnet contact 2 NC on magnet contact 5 Reset 6 Reset 7 NO on magnet contact 9 10 30 VDC 10 GND 15 17 Manual UDR Plus...

Page 16: ...ded connection between terminal 3 and 4 the alarm will be reset l The lock bolt causes a connection between C and NO when the bolt is retracted which generates a warning signal The warning can be remo...

Page 17: ...Accessories Green 1 9033 7 Black 1 9033 8 Technical Data Attributes UDR Plus Power Supply 10 30 V DC IP classification IP40 IK classification IK07 Temperature 20 to 50 C 17 17 Manual UDR Plus...

Reviews: