UDR-plus with code lock and electric lock
The example shows a door where the code lock allows an entry duration equal to
the sum of the relay time on the code lock and alarm bypass time. If possible, use
only the relay time on the code lock to prevent bypassing the alarm when the door
has been closed again.
l
Magnet NO when the door is shut.
l
The alarm is reset using code.
l
Given that the alarm has not been activated, UDR is reset when the door is
shut if switching magnetic contact is used. If the alarm has been activated, it
has to be reset using code.
l
If the alarm is set of while the door is opened and a valid code is entered, the
alarm is reset and will remain bypassed until the door is closed again. When
the door is closed, UDR return to normal operation mode.
l
If
A66
is used, another door monitor can be connected to deactivate the
relay immediately when the door is shut. The magnet contact is connected
directly to the reset input, not via C2-NC2.