Axel Streamer RTX User Manual Download Page 23

            

ENG

 

23 

General Purpose Input Output (GP Option) 

 

The Streamer and InStreamer equipment allows 2 General Purpose (GP) Input and Output. The 
GP name are GPI6 and GPI7 for the inputs and GPO6 and GPO7 for the output 

 

GPInput 

 
In order to activate GP6 and GP7 inside Streamer, place directly on ground the “In” signal ( IN to 
GND) as shown in picture. 
 
It is already possible employs both connectrs GND. Please remember that IN and GND are directly 
connected to µProcessor (µP) equipment.  
Pay attention to don’t connect external voltage to this connectors.   
These connectors can be directly applied to Axel Technology equipments as BOBCAT and 
BoxRelè, already made in order to manage all kind of signals coming from CD player, MD Player, 
tape recorder, ISDN tunneling or Automation System. 
  

GPOut 

 

Inside InStreamer are presents two BiStable Relay, iIn order to employ the GPOut. 
These Relays allows TWO condition: NC and NO. 
 

NC = Normally Close 
NO = Normally Open  
C = Common Contact  

 
Details: 
When there are no activation in GPI the Relay contact stay on NC. When GPI become activated, 
the output relay change the contact closure versus NO, as showed in picture. 
In the example figure, a cc generator is connected in the common contact and the same point 
directly to LAMP1 and LAMP2. 
In GPI non-activation position, LAMP1 is ON, and LAMP2 is OFF 
In GPI Activation position, LAMP1 is OFF, and LAMP2 is ON 
Working votage = 5 Vcc 
Maximum Voltage (breakdown) = 100 Vcc 
 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Streamer RTX

Page 1: ...Tel 39 051 736555 Fax 39 051 736170 Regional BERGAMO Via Italia 1 24030 Medolago Bg Italy Tel 39 051 736555 Fax 39 051 736170 e mail info axeltechnology com web site www axeltechnology com User Guide...

Page 2: ...2...

Page 3: ...t represent a commitment on the part of the vendor This manual images could differ a bit from the equipment actual design Axel Technology SRL shall not be liable for any loss or damage whatsoever aris...

Page 4: ...4 TABLE OF CONTENTS 1 Streamer Control Software installation 5 2 Installation of STREAMER RX 8 2 How To Decode Audio Streaming With Streamer RX 14 3 How To Encode Audio Streaming With Streamer RTX 17...

Page 5: ...s available the CD with lot of information DOC and firmware upgrade or reinstallaer The software that must be installed to control the Streamer is Streamer Control 1 Select Streamer Control exe and pr...

Page 6: ...ENG 6 4 Select the destination folder 5 Select the Programm destination folder...

Page 7: ...ENG 7 6 The software will install all the driver dll and all the things necessary for the installation A reboot is necessary after the installation and suggested...

Page 8: ...he power jack of the device and the other end into the power outlet of the wall 4 After few seconds will play a typical sound if a network is founded 5 To verify the IP address assignement and manage...

Page 9: ...status detector shows DHCP NOT PRESENT procede from step 9 7 By clicking on device inside the list box you will have all the parameters of the item selected Parameters assigned to Streamer by DHCP se...

Page 10: ...ng Test there will be the streaming of an audio MP3 file to the IP address of Streamer selected The suond will be played through the headphone and the RCA pin Streamer only not In Streamer The audio p...

Page 11: ...fore IP values of Streamer have to be assigned manually We suggest to chose carefully your IP address or to contact you network administrator to avoid any conflict with other network devices 10 To set...

Page 12: ...work parameters starting from IP address to DNS address into the EEPROM column Click each Set button to store the relative value Default Parameters stored to Streamer memory Parameters assigned manual...

Page 13: ...the decoder audio function using UDP Streaming Test utility By clicking on the START button of UDP Streaming Test there will be the streaming of an audio MP3 file to the IP address of Streamer select...

Page 14: ...er RX For installation and configuration refer to Chapter 1 1 To manage the decoding parameters of Streamer you can use Streamer Control Verify that no firewall is active into your PC 2 Pushing Get Li...

Page 15: ...o mount the memory option on the Streamer RX board by upgrading it into Streamer RX version 5 You can check the Streamer RX proper decoding by the UDP Streaming Test By pressing the START button a sho...

Page 16: ...ENG 16...

Page 17: ...RTX For installation and configuration refer to Chapter 1 1 To manage the encoding parameters of Streamer you can use NS1 Tools software Verify that no firewall is active into your PC 2 Pushing Get Li...

Page 18: ...o use the 1 channel option Bit Reservoir to improve the streaming audio quality it have to set on 0 Quality The encoder uses Variable Bitrate Encoding VBR to realize optimal compression of the audio d...

Page 19: ...IN jacks unbalanced Mic Microphone input selector Dig Digital SPDIF audio input The digital input and output are available only for the Streamer equipedd with the optional service board Monitor Monito...

Page 20: ...X and Streamer RTX Streamer RTX Streamer RTX Streamer RX GPI 7 GPO 7 GPI 6 GPO 6 Streamer RX LEFT Ch LEFT Ch RIGHT Ch RIGHT Ch Audio Balanced INPUT GP INPUT GP OUTPUT Audio Balanced OUTPUT COLD COLD G...

Page 21: ...TX Streamer RTX Streamer RTX LEFT Ch LEFT Ch LEFT Ch LEFT Ch RIGHT Ch RIGHT Ch RIGHT Ch RIGHT Ch Audio Balanced INPUT Audio Balanced OUTPUT COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT GND GN...

Page 22: ...input and output connector board IOB Option The standard configuration allows three connectors as standard EIA RS 297 A recommendations Pin Function 1 Chassis ground cable shield 2 positive polarity...

Page 23: ...as BOBCAT and BoxRel already made in order to manage all kind of signals coming from CD player MD Player tape recorder ISDN tunneling or Automation System GPOut Inside InStreamer are presents two BiSt...

Page 24: ...close IN versus GND as showed below When GPO 6 and or GPI 7 are Activated Relay6 and Relay7 change from NC to NO Nominal Value Vn 12V In 500mA Maximum Value breakdown Vm 100V Im 1A InStreamer GPI 7 G...

Page 25: ...a 1 year ex works warranty Do not open the equipment The warranty shall be voided if any of the warranty seals are broken The manufacturer shall not be liable for damage of any kind deriving from or i...

Reviews: