Axcera-430B Type Acceptance Report
Test Report
February 2004
4-4
Table 4-2. Detected Video Frequency Response
VIDEO FREQUENCY
RELATIVE RESPONSE
200 kHz
+2 dB
500 kHz
0 dB
750 kHz
0 dB
1.0 MHz
+0.1 dB
1.25 MHz
0 dB
1.5 MHz
0 dB
2.0 MHz
+0.2 dB
2.5 MHz
+0.4 dB
3.0 MHz
0 dB
3.5 MHz
+0.3 dB
3.58 MHz
+0.1 dB
4.0 MHz
+1.0 dB
4.18 MHz
-1.0 dB
4.5 MHz
-20 dB
4.75 MHz
-30 dB
5.0 MHz
-44 dB
Figure 4-3. Graph of Detected Video Frequency Response
4.2.5 RF Sideband Response
The RF sideband response was recorded using the test setup shown in Figure 4-1. With
the output power set to 1000 watts peak of sync, the Tektronix TSG95 video generator
was adjusted to provide a cable sweep test signal and the RF sideband response was
recorded. Data from this test is provided in Table 4-3.
Photographs of the spectrum analyzer results are shown in Figure 4-4.
Summary of Contents for 430B