7
How
to
Test
Run
(Continued)
1c. Connect the Blower Unit to the Control Panel on the Existing Range Hood from other brands
• Identify the Neutral wire and the Speed wires from your existing Range Hood. Please note that your Range
Hood might be 3 speeds or 2 speeds only.
• Refer to the
Wire Connection Table
in Step 1b for wire connections. Connect the Neutral wire and Speed wires
accordingly.
• Due to the speeds of the Blower Unit NOT varied by voltage or frequency, this Blower Unit is
NOT
compatible
with the existing control panels that vary the voltage or frequency.
Caution
Before connecting the Blower Unit to the existing control panel,
make sure to
correctly identify the Neutral wire
and the Speed wires from the control panel
. Failure to do so will result in a
burnt motor
which is
NOT covered
in
the warranty.
2. Connect the Power Cord to a 120V power source and varify the functionality of each button to check if it's working
properly. Refer to Page 9 for functional details.
Note
DO NOT
install the Blower Unit if it's defective. Contact the seller immediately.