Venting Requirements

DO

•  Have the venting system go vertically from the 

range hood to the roof if possible.

•  Have 24"-30" distance between the cooktop and 

the range hood. 27" is recommended.

•  Use uniformed duct of 6" round duct or 3-1/4 x 10” 

rectangular duct or larger.

•  Use metal vent only. Rigid metal vent is 

recommended. Semi-rigid aluminum vent is also 
acceptable for easy connection. 

•  Make sure there is a minimum of 24" of straight 

vent between the elbows if more than 1 elbow is 
used.

•  Use minimal numbers of elbows and the 

shortest route for the venting system for a better 
performance.

•  Use silver tap or duct tap to seal all joints in the 

venting system.

•  Use caulking silicone to seal exterior wall or roof 

opening around the cap.

•  Always keep the duct clean to ensure proper airflow.

DO NOT

•  End the venting system in an enclosed area indoors.
•  Use plastic vent.
•  Use no more than three 90° elbows.
•  Install 2 elbows together.
•  Install the range hood outside of the recommended 

height.

•  Reduce the duct size below the recommended size.

Venting System Setup:

•  For RH-C06 models: This range hood is 6” top 

venting through the roof or wall.

•  For RH-R06 models: This range hood is 3-1/4 x 10” 

top or rear venting through the roof or wall.

   

            

  

                   

INSTALLATION 

PREPARATIONS 

      

Cabinet

Cabinet

Side

Wall

Cap

Range Hood

Range Hood

Stove Top

Stove Top

Roof Cap

Rear Venting Wall Exhaust

Top Venting Roof Exhaust

Cabinet

Side

Wall

Cap

Range Hood

Stove Top

Top Venting Wall Exhaust

* For RH-C06 & RH-R06 Models

* For RH-R06 Models Only

Summary of Contents for 6" Height Under Cabinet Series

Page 1: ...Range Hood OWNER S MANUAL 6 Height Under Cabinet Series Test Run Before Installation Ver RH R C06 2020A RH C06 Models RH R06 Models ...

Page 2: ...10 for general issues and solutions Please read all instructions carefully before proceeding further to prevent the risk of fire electric shock personal injury or damage to the range hood This manual provides a general insight on the installation and may not include solutions for all possible issues that may occur In case of this manual destroyed or lost please visit https www awoco com and downlo...

Page 3: ...Requirement 6 Installation 7 Installing the Range Hood 7 Connecting the Vent System 7 Electrical Connection 7 Installing the Baffle Filters 7 Completing the Installation 7 Range Hood Use 8 Range Hood Control Panel 8 Range Hood Care 9 Clean the Exterior Surfaces 9 Clean or Replace the Baffle Filters 9 Replace the LED Lamps 9 Range Hood Troubleshooting 10 Warranty 11 ...

Page 4: ...walls ceiliings attics crawl spaces or garages TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn the hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé Clean ventilatin...

Page 5: ...g system Use caulking silicone to seal exterior wall or roof opening around the cap Always keep the duct clean to ensure proper airflow DO NOT End the venting system in an enclosed area indoors Use plastic vent Use no more than three 90 elbows Install 2 elbows together Install the range hood outside of the recommended height Reduce the duct size below the recommended size Venting System Setup For ...

Page 6: ... performance and efficiency Minimum Duct Size Round 6 minimum Rectangular 3 1 4 x 10 minimum IMPORTANT Observe all governing codes and ordinances It is the customer s responsibility To contact a qualified electrical installer To ensure that the electrical installation is in compliance with applicable codes and standards Electrical Requirements A 120V 60Hz AC only 15A fused electrical circuit is re...

Page 7: ...ottom of the cabinet Make sure the range hood is securely mounted before releasing For a more secure installation install additional screws into the pre drilled holes on the backplate of the range hood to secure it to the studs or lumbers If the pre drilled holes don t align with the studs or lumbers drill new holes on the backplate instead Connecting the Vent System Use 6 round or 3 1 4 x 10 rect...

Page 8: ...elayed Auto Shutoff function Press the Power button the 3rd time will shutoff the range hood immediately Delayed Auto Shutoff Function When the hood is operating in any speed press the Power button once will activate the Delayed Auto Shutoff function The range hood will shutoff automatically in 3 minutes While the Delayed Auto Shutoff function is activated press the Power button again and the hood...

Page 9: ...Filters Pull the spring release handle and remove the filter by pulling it down Wash the filter in the top rack of the dishwasher or with warm soapy solution manually Let the filters dry thoroughly Make sure the spring release handle is toward the front align and insert the filter Pull the spring release handle and push the filter into position Release the handle Repeat the steps for the remaining...

Page 10: ...d or the damper half circular flapper is not installed correctly or opening properly A tight mesh on a side wall cap might also cause restriction to the air flow The lights work but the blower is not spinning at all or is rattling The blower might be jammed or scraping the bottom due to shipping damage Disconnect the power cord remove the fan grill and the fan blade might see the fan blade or and ...

Page 11: ...inless steel baffle filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks on the product caused by transportation and handling Damage of product caused by accidents pests and vermin lightning wind fire floods or acts of God Damage of product caused by unauthorized modification or ...

Page 12: ...Website www awoco com Customer Support 1 888 412 3428 ...