background image

                                                                                                                                     

Steps To Test Run Before Installation

IMPORTANT! 

Wear gloves to protect against sharp edges.

PLEASE FOLLOW THESE INSTRUCTIONS TO TEST THE 
RANGE HOOD BEFORE INSTALLATION FOR ANY DEFECTS 
OR SHIPPING DAMAGE:

1.  Remove the range hood and accessories from the 

package carefully.

2.  Place the range hood on a flat stable surface, 

remove the baffle filter and check for any dents or 
damages on the range hood body.

3.  Remove the loosen parts if there's any.
4.  Plug the range hood into a 120V AC power source. 

Press the power button once and then any of the 
speed buttons to turn it on.

5.  Check each speed variation and pay attention to 

the noise level to make sure there isn't any unusual 
noise besides it coming from the wind blowing. 
Press the Light Button to check the lights.

6.  Verify all functions, as instructed in Page 8, are 

working properly.

7.  Refer to Range Hood Troubleshooting in Page 10 for 

general issues and solutions.

Please read all instructions carefully before proceeding 
further to prevent the risk of fire, electric shock, personal 
injury or damage to the range hood. This manual 
provides a general insight on the installation and may 
not include solutions for all possible issues that may 
occur. 

In case of this manual destroyed or lost, please visit 
https://www.awoco.com and download a digital version.

Installation Overview

1.  Unpack the range hood and check for any physical 

damage on the body.

2.  Test run the range hood and check if all functions 

are working properly. Refer to Page 8

 

for 

functionalities.

DO NOT

 

install the range hood if it's defective. Contact 

the seller immediately.

3.  If all is fine, install the range hood as instructed in 

this manual. Refer to Page 7.

4.  Test run the range hood again when the installation 

is finished. Refer to Page 10

 

for troubleshooting.

Possible Tools Needed:

•  Marker / Pencil;
•  Jig Saw or Reciprocating Saw;
•  Screwdrivers or Power Drill;
•  Level;
•  Measuring Tape;
•  Knife:
•  Duct / Foil Tape;
•  Screws.

2 PEOPLE ARE REQUIRED FOR THE INSTALLATION.

                                                                                                                                     

Summary of Contents for 6" Height Under Cabinet Series

Page 1: ...Range Hood OWNER S MANUAL 6 Height Under Cabinet Series Test Run Before Installation Ver RH R C06 2020A RH C06 Models RH R06 Models ...

Page 2: ...10 for general issues and solutions Please read all instructions carefully before proceeding further to prevent the risk of fire electric shock personal injury or damage to the range hood This manual provides a general insight on the installation and may not include solutions for all possible issues that may occur In case of this manual destroyed or lost please visit https www awoco com and downlo...

Page 3: ...Requirement 6 Installation 7 Installing the Range Hood 7 Connecting the Vent System 7 Electrical Connection 7 Installing the Baffle Filters 7 Completing the Installation 7 Range Hood Use 8 Range Hood Control Panel 8 Range Hood Care 9 Clean the Exterior Surfaces 9 Clean or Replace the Baffle Filters 9 Replace the LED Lamps 9 Range Hood Troubleshooting 10 Warranty 11 ...

Page 4: ...walls ceiliings attics crawl spaces or garages TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn the hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé Clean ventilatin...

Page 5: ...g system Use caulking silicone to seal exterior wall or roof opening around the cap Always keep the duct clean to ensure proper airflow DO NOT End the venting system in an enclosed area indoors Use plastic vent Use no more than three 90 elbows Install 2 elbows together Install the range hood outside of the recommended height Reduce the duct size below the recommended size Venting System Setup For ...

Page 6: ... performance and efficiency Minimum Duct Size Round 6 minimum Rectangular 3 1 4 x 10 minimum IMPORTANT Observe all governing codes and ordinances It is the customer s responsibility To contact a qualified electrical installer To ensure that the electrical installation is in compliance with applicable codes and standards Electrical Requirements A 120V 60Hz AC only 15A fused electrical circuit is re...

Page 7: ...ottom of the cabinet Make sure the range hood is securely mounted before releasing For a more secure installation install additional screws into the pre drilled holes on the backplate of the range hood to secure it to the studs or lumbers If the pre drilled holes don t align with the studs or lumbers drill new holes on the backplate instead Connecting the Vent System Use 6 round or 3 1 4 x 10 rect...

Page 8: ...elayed Auto Shutoff function Press the Power button the 3rd time will shutoff the range hood immediately Delayed Auto Shutoff Function When the hood is operating in any speed press the Power button once will activate the Delayed Auto Shutoff function The range hood will shutoff automatically in 3 minutes While the Delayed Auto Shutoff function is activated press the Power button again and the hood...

Page 9: ...Filters Pull the spring release handle and remove the filter by pulling it down Wash the filter in the top rack of the dishwasher or with warm soapy solution manually Let the filters dry thoroughly Make sure the spring release handle is toward the front align and insert the filter Pull the spring release handle and push the filter into position Release the handle Repeat the steps for the remaining...

Page 10: ...d or the damper half circular flapper is not installed correctly or opening properly A tight mesh on a side wall cap might also cause restriction to the air flow The lights work but the blower is not spinning at all or is rattling The blower might be jammed or scraping the bottom due to shipping damage Disconnect the power cord remove the fan grill and the fan blade might see the fan blade or and ...

Page 11: ...inless steel baffle filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks on the product caused by transportation and handling Damage of product caused by accidents pests and vermin lightning wind fire floods or acts of God Damage of product caused by unauthorized modification or ...

Page 12: ...Website www awoco com Customer Support 1 888 412 3428 ...