AwiDESULF combi-package for microbiological desulphurisation
8.5
Electrical Connection
DANGER
Dangerous electrical voltage is present at the terminals in the terminal box and the cables fed. An
incorrect connection may lead to electrical hazards and even death. For information on the allocation
of the different terminals and the wiring in the terminal box, please refer to the electric diagram
provided as part of the system. Check the connections afterwards.
WARNING
Incorrectly dimensioned cables can lead to fire and electrical hazards. Use only cables as specified.
The connection of AwiDESULF is implemented according to the provided electric diagram.
The solenoid valves for the distribution are electrically triggered and powered by the gas analysis
system.
Specification Connection Cable Valves:
AWG16 (metric equivalent 1.5mm²)
75°C / copper wire only (75°C / copper).
The power supply for AwiDESULF 100 also takes place via the gas analysis system.
The power supply for AwiDESULF 100 UL/CSA also takes place via the gas analysis system.
The power supply for AwiDESULF 200 also takes place via the gas analysis system.
The power supply for AwiDESULF 200 UL/CSA also takes place via the gas analysis system.
For AwiDESULF 300, the power supply of the compressor takes place on-site.
The respective feed line has 3 pins (3x1.5²) 220 – 240 V
For AwiDESULF 500, the power supply of the compressor takes place on-site.
The respective feed line has 3 pins (3x1.5²) 220 – 240 V
For AwiDESULF 1000, the power supply of the compressor takes place on-site.
The respective feed line has 3 pins (3x1.5²) 220 – 240 V
Specification Connection Cable Power Supply:
AWG16 (metric equivalent 1.5mm²)
55