AWID Sentinel-Sense ADB-512 Installation & Operation Manual Download Page 4

ADB-512

2.8 Label and compliance

The  final  end  product
“Contains  FCC  ID:  OG
when all FCC complian

2.9 Information on test mo

This  transmitter  is  test
any  co-located  or  sim
portable use will requir
new certification.

2.10 Additional testing, Pa

This transmitter module
cover  the  FCC  Part  1
applicable  to  the  final 
compliance to this porti

As long as all conditions a

required. However, the OE

product for any additional co

installed.

IMPORTANT NOTE:

In the ev

certain laptop configurations o
authorization is no longer con
product. In these circumstance
the end product (including the

Manual Information to the E

The OEM integrator has to be
regarding how to install or rem
product which integrates this m
The end user manual shall incl
in this manual.

OEM/Host manufacturer res

OEM/Host manufacturers are 
Module. The final product must
the FCC rule such as FCC Pa
This includes reassessing the
EMF essential requirements o
into any other device or system
combined

- 4 -

7/

information

ct  must  be  labeled  in  a  visible  area  with  t

GSADB512”.  The  grantee’s  FCC  ID  can  b

nce requirements are met.

odes and additional testing requirements

ted  in  a  standalone  mobile  RF  exposure  co
multaneous  transmission  with  other  tran

re a separate class II permissive change re-

art 15 Subpart B disclaimer

le is tested as a subsystem and its certifica

15  Subpart  B  (unintentional  radiator)  rule

host.  The  final  host  will  still  need  to  be  re

ion of rule requirements if applicable.

above are met, further transmitter test will no

EM integrator is still responsible for testing th

compliance requirements required with this 

vent that these conditions cannot be met (fo

or co-location with another transmitter), then

nsidered valid and the FCC ID cannot be use

ces, the OEM integrator will be responsible fo

e transmitter) and obtaining a separate FCC 

End User

e aware not to provide information to the end
move this RF module in the user’s manual of

module.

clude all required regulatory information/war

sponsibilities

 ultimately responsible for the compliance o

st be reassessed against all the essential re

art 15 Subpart B before it can be placed on t

e transmitter module for compliance with the

of the FCC rules. This module must not be in

m without retesting for compliance as multi-

7/19/2021

the  following:

be  used  only

condition  and

nsmitter(s)  or

-evaluation or

cation does not

e  requirement

eassessed  for

ot be

heir end-

s module

or example

n the FCC

ed on the final

or re-evaluating

FCC authorization.

d user

of the end

rning as show

of the Host and

equirements of

the US market.

e Radio and

ncorporated

-radio and

Summary of Contents for Sentinel-Sense ADB-512

Page 1: ...ADB 512 SENTINEL Installation 1 7 NEL SENSE ADB 512 Operation Manual 0415 7 19 2021 527...

Page 2: ...ed and is believed t or inaccuracies AWID reserves the right to ma ment is not covered by any warranty either exp ctions or additions to the contents of this docum address in USA roperty of their resp...

Page 3: ...KDB 996369 llowing conditions must be strictly followed Manual v01 rule sections CC rules tested for compliance to FCC Part 15 ic operational use conditions for standalone mobile RF exposure use co s...

Page 4: ...h other tran re a separate class II permissive change re art 15 Subpart B disclaimer le is tested as a subsystem and its certifica 15 Subpart B unintentional radiator rule host The final host will sti...

Page 5: ...interference that rme aux CNR d ISED applicables aux appa ation est autoris e aux deux conditions suiva de brouillage pr judiciable et 2 ce disposi y compris un brouillage susceptible de prov ent with...

Page 6: ...ssible maximal Les types d antenne non inclus dans cette liste et dont le gain est sup rieur au gain maximal indiqu pour tout type figurant sur la liste sont strictement interdits pour l exploitation...

Page 7: ...ui Le manuel de l utilisateur final requises et avertissements co 7 7 nd User o be aware not to provide information to remove this RF module in the user s man module nclude all required regulatory inf...

Page 8: ...AM 5 1 System Operation 5 1 1 Running a Custo 5 2 Users Note 6 REFERENCE NOTE RE NOTE FAILURE TO FOLLOW POOR PERFORMANCE OR READER THUS VOIDS THE 8 7 Table of Contents PLIANCE Table gnment stance RATI...

Page 9: ...ID Engineering 0 2 AWID Engineering 0 3 AWID Engineering 9 7 REVISION HISTORY Date Sections Affected Rema g 6 2021 Initial version g 7 2021 p 5 Editorial IC Complia g 7 2021 p 2 p 5 Updated FCC IC C 7...

Page 10: ...ams are applicati 10 7 512 is a 4 port long range Radio Frequency 3 V TTL logical interface that works with mo dule comes with a unique combination of lo nsumption Its primary applications are asse ge...

Page 11: ...kHz typical Pseudo random 30 C to 65 C 22 F to 149 F 3 3V TTL Serial 10 pin ZIF 2 11 x4 25 x0 35 QUENCY TABLE 927 40 MHz Minimum number of frequency cha MHz CH 902 928 MHz CH 902 928 MHz MHz 50 912 60...

Page 12: ...hin three 3 inches of the t 12 7 IN ASSIGNMENT Pin Function 6 GND 7 Unit Enable 8 SCIR 9 SCIT 10 GND ally pulled high User may leave this pin unc d READ DISTANCE g types For certain readers and tags u...

Page 13: ...longe source 13 7 OPERATION GUIDELINES R reader in this section refers to an RFID dev gh performance circular polarized antenna i case The module should be installed on a h be an aluminum plate of si...

Page 14: ...e demo software Select COM port 1 commands 14 7 PROCEDURE on and operation information for ADB 512 read ow are present before starting the installatio 512 FOR INSTALLATION connectors and pin out assig...

Page 15: ...ication Protoco MPR Command Demo II Quick 15 7 GRAMMING AND SYSTEM OPERATION NO ATION om Software Application or the AWID Demo t used it is expected user will launch a Cust he MPR Communication Protoc...

Reviews: