17
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put the 1
st
bridge between terminals 1 and 2, the 2
nd
between terminals 2 and 3 and the 3
rd
between terminals 4 and 5.
Attach the earth to the terminal
“earth”, the neutral N to terminal 4 or 5, the Phase L1 to one of
the terminals 1, 2 or 3.
Biphase
400V~2P+N
Put the 1
st
bridge between terminals 1 and 2, the 2
nd
between terminals 4 and 5
Attach the earth to the terminal
“earth”, the neutral N to terminal 4 or 5, the Phase L1 to the
terminals 1 or 2 and the Phase L2 to the terminal 3.
Triphase
400V~3P+N
Put a bridge between terminals 4 and 5.
Attach the earth to the terminal
“earth”, the neutral N to terminal 4 or 5, the Phase L1 to the
terminal 1, the Phase L2 to the terminal 2.and the Phase L3 to the terminal 3.
Caution! Be careful that the cables are correctly engaged and tightened.
Award cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.