16
ELECTRICAL CONNECTION
The installation of this appliance and the connection to the electrical network should be
entrusted only to a suitably qualified service agent perfectly to the fact of the normative
regulations and which respects them scrupulously.
Protection against the parts under tension must be ensured after the building-in.
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or even.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz.
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 4 mm²
H 05 VV
– F
H 05 RR
– F
40 A *
400V~ 50/60Hz 2 N
4 x 2.5 mm²
H 05 VV
– F
H 05 RR
– F
25 A *
400V~ 50/60Hz 3 N
5 x 1.5 mm²
H 05 VV
– F
H 05 RR
– F
16 A *
* calculated with the simultaneous factor following the standard EN 60 335-2-6