3.– MAKING THE OPENING

I

 

If the ceiling hood is going to be fitted between the joists, the air exhaust duct position can be placed on the 
short side, only, and the opening dimensions will be as detailed in 

A OPTION

, only.

 

 
If the ceiling hood is going to be installed with threaded rods, it will can be installed according to 

the opening 

dimensions

 detailed in option A or 

the opening dimensions

 detailed in 

B OPTION

, as seen in page 2. 

 

REMARK: 

300mm x 300mm is the opening reserved to make easy the attach of the 

air exhaust duct to 

the hood air outlet

. It will be closed when this task is finished. 

E-295 CEILING HOOD INSTALLATION GUIDE 

Page 4 

4.–  HOLDING IN THE CEILING   

 
There are two ways to hold the ceiling hood: 

A SYSTEM

 - Using 

threaded rods (

M8 size) to adjust the length between the rough ceiling and the suspended 

ceiling. 

B SYSTEM

 - Fitting between the joists. 

 

REMARK! 

The M8 size 

threaded rods are not supplied with the provided 

accesories. 

Please read carefully the following instructions to adjust the threaded rods with the correct length. 
The hood can be damaged if these instructions are not followed to the letter. 

A SYSTEM

 - Using 

threaded rods (

M8 size). 

EXTERNAL MOTOR VERSION

 

INTERNAL MOTOR VERSION

 

Summary of Contents for E-295

Page 1: ...INTERNAL MOTOR VERSION A Fitting System EXTERNAL MOTOR VERSION B Fitting System E 295 CEILING HOOD INSTALLATION GUIDE ...

Page 2: ......

Page 3: ...ceiling must be 296mm and the maximum distance from floor to the ceiling should not be higher than 2 5m in order to maintain 1 INITIAL CKECKING LIST MINIMUM DISTANCE 2 AIR EXHAUST DUCT 2 1 The section of the air exhaust duct that will be attached to the hood air outlet should be Ø150mm A shape adaptor will be required to attach the 90 x 180mm rectangular outlet to a circular section air exhaust du...

Page 4: ...ion If required please follow the following instructions 1 Open the panel of the ceiling hood 2 Dismantle and remove the filtres 3 Unscrew the motor box 4 Rotate the motor box until the required position 5 Screw the motor box 6 Assemble the filters 7 Close the panel of the ceiling hood INTERNAL MOTOR VERSION EXTERNAL MOTOR VERSION Page 3 ...

Page 5: ...h of the air exhaust duct to the hood air outlet It will be closed when this task is finished E 295 CEILING HOOD INSTALLATION GUIDE Page 4 4 HOLDING IN THE CEILING There are two ways to hold the ceiling hood A SYSTEM Using threaded rods M8 size to adjust the length between the rough ceiling and the suspended ceiling B SYSTEM Fitting between the joists REMARK The M8 size threaded rods are not suppl...

Page 6: ... suspended ceiling the length L inserted in the rough ceiling is not included minus 65mm according to the following image 36 mm ceiling hood thickness 29 mm allowed tolerance to avoid damaging the hood Image and dimensions valid for both motor versions internal and external B SYSTEM Fitting between the joists Page 5 ...

Page 7: ... B Fitting between the joists E 295 CEILING HOOD INSTALLATION GUIDE Page 6 To wear the holes in the ceiling please select the right fitting option Option A Fitting the ceiling hood with M8 size threaded rods ...

Page 8: ...PARING THE CEILING HOOD TO BE FITTED E 295 CEILING HOOD INSTALLATION GUIDE One end from the Ø150 exhaust duct will hang downwards about 30 cm from the suspended ceiling Cut and remove the excess lenght to avoid any unwanted elbow when the duct is attached to the ceiling hood air outlet The other end will be connected to the duct run REMARK Try to seal the junctions between the adaptor and the duct...

Page 9: ...etween the suspended ceiling and the support must be 36 mm when the nuts are tapped so the ceiling hood will be placed at the required height OPTION A FITTING THE CEILING HOOD WITH M8 SIZE THREADED RODS E 295 CEILING HOOD INSTALLATION GUIDE Once the threaded rods are tapped in the rough ceiling and placed in the supports at the required height the ceiling hood wil be raised and fixed with the prov...

Page 10: ... INSTALLATION GUIDE Page 9 OPTION B FITTING BETWEEN THE JOISTS Fit the hood in the opening so that the edge of the hood must be completely aligned with the suspended ceiling Fix it to the wood rawlplug previously drilled ...

Page 11: ...other electric devices connected to the same network like fluorescent lights The supply connector should be approachable to be plugged and unplugged Otherwise a switch should be provided and installed according to the local electrical regulations The electrical connection must be wired according to the local electric regulations Any liability will be declined in case of an accident origined by a m...

Page 12: ...ARNING Before plugging it disconnect all sources of electric power until all the installation tasks are completely finished Once the hood is powered on verify that all the air conducts are sealed before closing the opening on the suspended ceiling 6 SWITCHING ON The ON OFF button is placed under the filters Open the front panel and remove the filter to switch it on off REMARK Please follow the ins...

Page 13: ...n on the swith from the main electrical switchboard or turn the ceiling hood switch button to ON 3º Press the LIGHT button on your remote control during the 15 seconds after the hood is powered and switched on so that the hood can receive the synchronisation signal 4º The synchronisation process will end when the ceiling hood lights turns on REMARK Press the LIGHT button on your remote control dur...

Page 14: ...t panel Before placing the light panels plug the connectors adjust the light panels and press slightly to fit them Your ceiling hood is ready E 295 CEILING HOOD INSTALLATION GUIDE Page 13 7 PLACE THE FILTER AND CLOSE THE FRONT PANEL Award ...

Page 15: ......

Page 16: ...Award Appliances NZ Limited E mail sales award co nz www awardappliances co nz ...

Reviews: