OPERATION

WARNING: 

Improperly attached hoses or accessories can become detached under 

pressure  and cause serious injury. Possible air leaks can cause faulty pressure 

readings. Make sure all connections are tightly secured.

If self-locking swi ch is up, turn it down .

Press “ON/Unit” button to read the current tire pressure on the gauge. Press “ON/Unit” button

again to select tire pressure measurement unit from PSI, KPA, BAR, KG/CM.

Press the “+” or“-” button to adjust the preset tire pressure to the required tire pressure.

hold the or button down to adjust working pressure quickly, (set value runs up  or down  faster)

press the “+”or ”-” button briefly to adjust the pre-set working pressure in small steps by 0.05

BAR & KG/CM, or by 1 PSI, 5KPA.

8. Press the On/Off trigger switch to start inflating.

When the pressure reaches the pre-set pressure value, the device will stop inflating.

NOTE: 

To reset the tire pressure measurement unit, press "ON/Unit" to reselect after setting 

             preset pressure value.

NOTE: 

Digital gauge records the preset measurement unit and value of last time operation

NOTE: 

After the air pump reaches the preset pressure value, the digital gauge will go off after 

            30 seconds, and the device will shut down automatically.

NOTE: 

Maximum PSI for this unit is 100PSI.

!

Always leave the hose free of obstructions when the tool is not in use. Overheating could 

occur if the hose is blocked.

ACCESSORIES

The supplied accessories perform a variety of functions. The tapered 

 can be used on 

smaller pinch valves to inflate small items like children’s toys, which usually require the user 

to inflate them by blowing air into them. The sport

needle can be used to inflate any 

type of sports ball or any other item that requires an inflation needle.

  NOTE:

 When inflating items of 10 PSI or less, inflate in short bursts and check after each burst 

with a calibrated measuring device to determine accurate pressure.

:

Insert needle into ball valve and inflate.

Remove needle after inflation.

NOTE: 

Pressure required for most sports balls is too low for accurate reading on tool gauge.

NOTICE: 

Fig.1

Air chuck clamp

in unlocked 

position

B Air chuck clamp in

locked position 

C Valve stem

D Air chuck

E Air hose

F Air chuck clamp

C

D

E

F

8

Summary of Contents for C192069

Page 1: ...PRODUCT CODE C192069 Operator s Manual 20 VOLTS CORDLESS INFLATOR ...

Page 2: ...ion A moment of inattention while operating inflator may result in serious personal injury Dress properly Do not wear loose clothing or jewellery Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts Do not overreach Keep proper footing and balance at all times Proper footing and balance enable better control of...

Page 3: ... of shock or injury Know your inflator Read operator s manual carefully Learn its applications and limitations as well as the specific potential hazards related to this tool Following this rule will reduce the risk of electric shock fire or serious injury Risk of bursting Do not operate inflator to result in output pressure greater than marked maximum pressure of item to be inflated Do not use at ...

Page 4: ...placed by an authorised service center Inspect tool cords periodically and if damaged have repaired at your nearest Authorised Service Center Constantly stay aware of cord location Risk of bursting Carefully monitor objects during inflation To reduce the risk of over inflation use a reliable pressure gauge periodically during inflation The pressure on the inflator is for reference only and is ther...

Page 5: ...FUNCTIONAL DESCRIPTION B F I H G C E A D Rubber covered handle Air hose Air chuck Digital pressure gauge Hose storage area Battery Start switch Self ocking switch LED light 5 ...

Page 6: ...To remove battery pack from the tool press the lock spring buttons and pull out To insert simply push pack in until lock spring clicks The battery charger consists of two parts witching adapter 240 volt plug with a low voltage lead harging stand To recharge battery the switching adapter plug low voltage lead to the charging stand Insert the switching adapter plug into a 240V household current rece...

Page 7: ...y for the user and of the tool After reaching the desired pressure press the Start switch The self locking switch will spring down USING THE INFLATOR See Figure 1 Install the battery pack Position air chuck clamp in the unlock position perpendicular to the air hose Place the air chuck on the valve stem Push the air chuck down so that the threaded section of the valve stem is inside the air chuck C...

Page 8: ...ds the preset measurement unit and value of last time operation NOTE After the air pump reaches the preset pressure value the digital gauge will go off after 30 seconds and the device will shut down automatically NOTE Maximum PSI for this unit is 100PSI Always leave the hose free of obstructions when the tool is not in use Overheating could occur if the hose is blocked ACCESSORIES The supplied acc...

Page 9: ...ed by their use Use clean cloths to remove dirt dust oil grease etc To maintain the best performance of your rechargeable battery protect it from overheating both from overcharging and during storage Charge the battery for 7 hours before the first time use 9 PARTS LIST NO DESCRIPTION 1 2 3 4 5 6 7 9 10 11 Left housing Absorber Digital gauge Air pump assembly Microswitch Trigger Spring 8 Motor Tors...

Page 10: ...SCHEMATIC DRAWING 10 ...

Reviews: