AV6A 22
CONNECTOR
OPTION
“C”
M12
POR
T
SIGNAL
PORT1
Tx+
1
Tx-
3
Rx+
2
Rx-
4
Power
+Vs
1
COM
3
NC
2
NC
4
PORT2
Tx+
1
Tx-
3
Rx+
2
Rx-
4
REF
SIGNAL
Rx+ **
Rx- **
Tx+ **
Tx- **
+V
COM
Optional Daisy-Chain
Rx+
Rx-
Tx+
Tx-
* NOTE: Twisted pair cable CAT6, CAT5E. Obey pairing as shown, optional overall shield may be
used for high noise environments
** NOTE: For encoder switch connections use the “crossover” pinout shown for encoder-PC or
encoder-PLC direct wiring use a “Straight through” connection (Tx+
Tx-, Rx+
Rx-, Rx-
Rx-)
Communication Bus “K”, “N”, “R”: POWERLINK, Profinet IO, EtherNet/IP Pinout
Pinouts for Ethernet
Port 2
Port 1
Power
Switches
AV6A WIRING DIAGRAMS
Master/Scanner
or Switch
Power Supply