OPERATOR MANUAL

IMPORTANT INFORMATION, KEEP FOR OPERATOR

Information contained in this document is known to be current and accurate at the time 

of  printing/creation.  Unified  Brands  recommends  referencing  our  product  line  websites, 

unifiedbrands.net, for the most updated product information and specifications.

1055 Mendell Davis Drive 

Jackson, MS 39272

888-994-7636, fax 888-864-7636

unifiedbrands.net

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. 

READ,  UNDERSTAND  AND  FOLLOW  THE  INSTRUCTIONS  AND 

WARNINGS CONTAINED IN THIS MANUAL.

NOTIFY CARRIER OF DAMAGE AT ONCE

It is the responsibility of the consignee to inspect the container upon receipt of 

same and to determine the possibility of any damage, including concealed dam-

age. Unified Brands suggests that if you are suspicious of damage to make a 

notation on the delivery receipt. It will be the responsibility of the consignee to file 

a claim with the carrier. We recommend that you do so at once.

Manufacture Service/Questions 888-994-7636.

PART NUMBER PP EA0711 REV A (08/11)

Summary of Contents for ecoarch

Page 1: ...net THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE READ UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the...

Page 2: ...Balance page 19 Final Air Balance Make Up Air Hood page 20 PeriodicMaintenance page21 Parts List page 22 Do not attempt to service this unit yourself as removing covers may cause unnecessary exposure...

Page 3: ...of product improvement Avtec reserves the right to make changes in design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recomme...

Page 4: ...rally installed in the exhaust plenum of an EcoArch canopy consisting of UVc filtration system designed for use in the ventilation control of commercial cooking operations of listed hood systems A dep...

Page 5: ...Avtec hoods are provided with adjustable hanging brackets designed to receive 1 2 threaded rod with a 1 2 nut and washer Supporting rods must be connected to all factory installed brackets Recommende...

Page 6: ...ll national regional and local codes that apply Read and review these instructions BEFORE attempting to install this unit For best results follow the installation sequence as described Follow steps 1...

Page 7: ...OM ECOARCH 7 Installation Instructions Figure 5...

Page 8: ...8 OM ECOARCH Installation Instructions Figure 5 Continued...

Page 9: ...anel is located remotely then installation is required Remote Located Control Locate terminal strip 2 TS 2 in relay box located on top of the hood This is where the UV light switch will terminate THE...

Page 10: ...10 OM ECOARCH Installation Instructions Figure 6a RELAY BOX BALLAST BOX...

Page 11: ...OM ECOARCH 11 Installation Instructions Figure 6b...

Page 12: ...12 OM ECOARCH Installation Instructions Figure 6c...

Page 13: ...nd airline cable on exhaust fan cap and metal curb Remember to leave ample room for fan to tilt back Fan will remain in tilted back position 7 Install grease collection box on side of fan that has gre...

Page 14: ...om the exhaust fan If 10 is not possible a 3 vertical separation may be acceptable 3 Cut and seal supply fan curb to roof 4 Duct shall be constructed of 22 or 24 gauge steel Insulated duct material sh...

Page 15: ...OM ECOARCH 15 Installation Instructions Figure 7 FOR CONTROL PANEL IF PROVIDED...

Page 16: ...the top and have a 90 bend inward at the rear 2 Skirts are to overlap the outside of the hood Bolts and acorn nuts should be attached per the drawing stainless bolts and acorn nuts supplied 3 Skirt fl...

Page 17: ...ure panels will be shipped with clips installed on perimeter of hood top where panels are to be installed 2 Slide enclosure panel under clips 3 If enclosure panels are installed on one or more hoods b...

Page 18: ...hood is hung it will rest on top panel NOTE Be careful to not damage wall panel face when installing hood 1 Install wall panels prior to hanging hood s 2 Install seam strips at proper locations and sc...

Page 19: ...s are captured 10 Same as step 7 with bottom of next page NOTE The exhaust and supply if any air flow rates were established under controlled laboratory conditions and greater exhaust and or lesser su...

Page 20: ...oking equipment under the hood and preheat to operating temperature 4 Produce large quantities of smoke or steam 5 Observe capture of vapors 6 If all vapors are not totally captured fine tune the syst...

Page 21: ...penings should be wiped down daily B Inspect inside of extraction chamber at least weekly to insure proper cleaning and that the trough and access door are free of foreign matter 6 UV Preventative Mai...

Page 22: ...RT NO DESCRIPTION 1 AS SEAL1001 Sight Glass 2 EL BLS1101 Ballast UVC Lamp 115V 3 EL CNT1104 Connector UV Lamp 4 EL CON1001 Magnetic Contacts 5 EL FUS0205 1 amp Fuse 6 EL FUS0307 10 amp Fuse 7 EL FUS11...

Page 23: ...OM ECOARCH 23 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Service Performed Performed By...

Page 24: ...ive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2011 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary of Dover Corporation PART NUMBER P...