background image

- 6 -

XSAT WS 4 EXPANSION

Installation Manual

General information

• 

The 

XSAT WS 4

 radio transceiver combines a traditional wire system with a line of wireless radio products (sensors, sirens and remote 

controls) that allow you to extend the protection of the system.

• 

This board is inserted in a thermoplastic container that optimizes its the performance.

• 

Depending on the installation needs, the 

XSAT WS 4

 can also be placed at a distance from the controller with which it is combined using 

the RS485 serial link.

• 

Manage up to 32 sensors

• 

Manage up to 64 remote controls 

• 

Manage 1 wireless siren

• 

2 terminal Input or Output 

• 

Multi-color LED indicator

General characteristics

Input lines

No 32 configurable with automatic detection of the individually programmable

alarm and anti-tamper status; each input can be programmed in one of the

possible modes of operation.

Terminal T1 and T2

n° 2:

 Input / Output. 

The terminals T1 and T2 can be programmed as either an input zone 7 and zone 8 of the satel-

lite with one resistor (alarm only) or double resostor (alarm and tamper), both as Open Collector 

outputs 7 and 8 with reference to negative; or both programs simultaneously (line input is unba

-

lanced directly by activation of the corresponding OC)

Capacity in open field

~ 200 meters

Programming:

from keyboard with guided menu

Connections:

Four-wire

Dimensions: (L x H x P):

119 x 83 x 10 mm

Container: (L x H x P)

129,5 x 92 x 15,5 mm

Environmental Conditions:

+5 °C / +55 °C

Voltage: 

13,8 V =

Current consumption:

At rest: 30 mA / Receiving: 45 mA / Transmission: 70 mA 

Protection grade:

IPX0

Bande di frequenza usate

Occupied frequency bands

(ETSI EN 300 220-3-2 V1.1.1 (2017-02) 

Wireless alarm equipment)

Massima 

potenza irradiata

Maximum 

radiated power

Numero di banda

Band number

According to EC Decision 

2013/752/EU [i.2]

Numero di sottoclasse 

della Classe 1

Class 1 sub-class number

Commision Decision 2000/299/EU [i.5]

A

868,600 MHz to 868,700 MHz

<10 mW e.r.p.

49

32

D

869,300 MHz to 869,400 MHz

<10 mW e.r.p.

53

72

E

869,650 MHz to 869,700 MHz

<10 mW e.r.p.

55

34

XSA

T WS 4  compatibility with AVS 

Electronics controllers

You can program, display and continuously monitor all functions of the 

XSAT WS 4 

satellite and the sensors via radio. Through an RS 485 serial 

connection, the system directly recognizes all zone and tamper alarms and all technical information linked to the radio equipment (sensor anti

-

masking, sensor survival, battery-low sensors and radio interference).

The satellite has to be installed at least 20 cm away from electrical appliances or metal containers that could disturb its operation.

The power supply must come from a very low voltage safety circuit and having the characteristics of a limited, fuse-protected power source.

INSTALLATION AND MAINTENANCE MUST BE PERFORMED BY QUALIFIED PERSONNEL

Satellite Card XSAT WS 4

ENTERING WIRES

Strip the cable for 3 - 4 mm and with soft pres

-

sure insert it into the corresponding.terminal.

CABLES DISCONNECTION

With a screwdriver, press lightly 

at the point indicated in the figu

-

re,  and  pull  out  simultaneously 

the cable from its housing.

ON

12

34

56

78

TAMPER

S1

1

1

2

3

-

T T2 T1

-

DB DA

+

ON

12

34

56

78

Summary of Contents for XSAT WS 4

Page 1: ...ttromagnetica SCHEDA SATELLITE Via Radio XSAT WS 4 SISTEMA DI QUALITA CERTIFICATO UNI EN ISO 9001 2008 Via Valsugana 63 35010 Padova ITALY Tel 049 9698 411 Fax 049 9698 407 avs avselectronics it www avselectronics com assistenza tecnica 049 9698 444 support avselectronics it I T A ...

Page 2: ... mA In ricezione 45 mA In trasmissione 70 mA Grado di protezione IPX0 Bande di frequenza usate Occupied frequency bands ETSI EN 300 220 3 2 V1 1 1 2017 02 Wireless alarm equipment Massima potenza irradiata Maximum radiated power Numero di banda Band number According to EC Decision 2013 752 EU i 2 Numero di sottoclasse della Classe 1 Class 1 sub class number Commision Decision 2000 299 EU i 5 A 868...

Page 3: ...aso di doppio canale la configurazione di entrambi i sensori va fatta esclusivamente su quello con l indirizzo più basso Parametro 8 Impulsi inerziale Switch Alarm nel sensore radio WIC 4 WIC 4 Plus è possibile regolare il numero di impulsi per l allarme dell ingresso IN1 1 Molto sensibile 16 Poco sensibile Parametro 9 Abilita vibrazione nel sensore radio WIC 4 Plus impostando a SI si attiva la fu...

Page 4: ...di centrale spenta quando l o c si attiva e nessuno quando si disattiva Nel BIP 4 Plus si accende il led verde e il buzzer emette due suoni lunghi quando l o c si attiva e nulla quando l o c si disattiva Con alcuni modelli più evoluti di centrale anche per la programmazione della sirena radio fare riferimento solo a quanto riportato nel ma nuale della centrale stessa Informazioni in conformità con...

Page 5: ... on electromagnetic compatibility SATELLITE RADIO BOARD XSAT WS 4 UNI EN ISO 9001 2008 CERTIFIED QUALITY SYSTEM Via Valsugana 63 35010 Padova ITALY Tel 049 9698 411 Fax 049 9698 407 avs avselectronics it www avselectronics com support avselectronics it E N G ...

Page 6: ...rrent consumption At rest 30 mA Receiving 45 mA Transmission 70 mA Protection grade IPX0 Bande di frequenza usate Occupied frequency bands ETSI EN 300 220 3 2 V1 1 1 2017 02 Wireless alarm equipment Massima potenza irradiata Maximum radiated power Numero di banda Band number According to EC Decision 2013 752 EU i 2 Numero di sottoclasse della Classe 1 Class 1 sub class number Commision Decision 20...

Page 7: ... In case of double channel configuration of both the sensors must be made exclusively on the one with the lowest address Parameter 8 Puls inert SW AL in the WIC 4 WIC 4 Plus radio sensor it is possible to adjust the number of pulses of the input alarm IN1 1 High sensitivity 16 Low sensitivity Parameter 9 Vibration enable in the WIC 4 WIC 4 Plus radio sensor setting to YES enables the integrated ac...

Page 8: ...flash does a controller on when the OC is activated and none when it is deactivated BIP 4 Plus when the o c is activated the green LED lights up and the buzzer sounds two beeps and when the o c is deactivateed nothing happen For programming the wireless siren of some of the more advanced controller models refer only to what is shown in the controller manual Information in accordance with Directive...

Page 9: ... la compatibilité électromagnétique CARTE SATELLITE par voie Radio XSAT WS 4 SYSTÈME QUALITÉ CERTIFIÉ UNI EN ISO 9001 2008 Via Valsugana 63 35010 Padova ITALY Tel 049 9698 411 Fax 049 9698 407 avs avselectronics it www avselectronics com support avselectronics it F R A ...

Page 10: ...ant absorbé Au repos 30 mA Pendant la réception 45 mA Pendant la transmission 70 mA Degré de protection IPX0 Bande di frequenza usate Occupied frequency bands ETSI EN 300 220 3 2 V1 1 1 2017 02 Wireless alarm equipment Massima potenza irradiata Maximum radiated power Numero di banda Band number According to EC Decision 2013 752 EU i 2 Numero di sottoclasse della Classe 1 Class 1 sub class number C...

Page 11: ...s WIC4 qui va provoquer une alarme peut être réglé de 1 très sensible à 16 peu sensible Parametro 9 Vibration actif les contacts magnétiques WIC4 et WIC4 ont également un détecteur de vibration Ce pas de programmation permet de l activer Parametro 10 Sensibilité vibration pour régler le détecteur de vibration desWIC4 1 Très sensible 8 Peu sensible Parametro 11 Nombre d impulsions de vibration dans...

Page 12: ...lumée quand la sortie Open Collector s active et aucun lorsqu elle se désactive BIP 4 Plus quand O C est activé la LED vert allumée et le buzzer retentit et lorsque le oc est désactivé rien arriver Avec certains modèles plus évolués de centrale pour la programmation de la sirène radio également se référer uniquement à ce qui est indiqué dans le manuel de la centrale Informations en conformité avec...

Page 13: ...tromagnetische Verträglichkeit SATELLITE RADIO BOARD XSAT WS 4 ZERTIFIZIERTES QUALITÄTSSYSTEM UNI EN ISO 9001 2008 Via Valsugana 63 35010 Padova ITALY Tel 049 9698 411 Fax 049 9698 407 avs avselectronics it www avselectronics com support avselectronics it D E U ...

Page 14: ...r 5 C bis 55 C Versorgungsspannung 13 8 V Stromaufnahme in Ruhe 30 mA in Empfang 45 mA in Übertragung 70 mA Schutzart IPX0 Bande di frequenza usate Occupied frequency bands ETSI EN 300 220 3 2 V1 1 1 2017 02 Wireless alarm equipment Massima potenza irradiata Maximum radiated power Numero di banda Band number According to EC Decision 2013 752 EU i 2 Numero di sottoclasse della Classe 1 Class 1 sub ...

Page 15: ... 4 25 einzustellen Parameter 7 Akti IN 1 Eingang Ermöglicht den Eingang IN1 der Funk Melder WIC 4 WIC 4 Plus durch JA zu aktivieren HINWEIS Bei Doppelkanal muss die Konfiguration beider Melder ausschließlich an der mit der niedrigeren Adresse vorgenommen werden Parameter 8 Anzahl Impulse Eingang Ermöglicht die Anzahl der Alarmimpulse des Eingangs IN1 der Funk Melder WIC 4 WIC 4 Plus einzus tellen ...

Page 16: ...s passiert nichts bei Deaktivierung BIP 4 Plus Wenn der OC aktiviert wird leuchtet die grüne LED auf und der Summer ertönt zweimal kurz und bei OC Deaktivierung passiert nichts Die Programmierung der Funksignalgeber in Verbindung mit weiteren Zentralen ist in dem entsprechenden Handbuch der Zentrale nach zulesen Information gemäß der Richtlinie 1999 5 cee r tte Das hier beschriebene Produkt entspr...

Reviews: