- 14 -
FUNCTIONS
NUMBER OF GREEN LED IMPULSES
1
2
3
4
5
6
7
8
NUMBER OF RED LED IMPULSES
1
SA unbalancing
Negative to
remove
Negative to
give
POSITIVE
TO
REMOVE
Positive to
give
Negative to
remove with
4k7 Ohm re-
sistance
N e g a t i v e
to give with
4k7 Ohm re-
sistance
Positive to
remove with
4k7 Ohm re-
sistance
Positive to
g i v e w i t h
4 k 7 O h m
resistance
The SA input can be balanced to negative to give or remove with or without 4k7 Ohm resistance or to
positive to give or to remove with or without 4k7 Ohm resistance.
If the changing of this parameter is done with the siren already powered,
when exiting the program-
ming the SA input needs to be rebalanced to
restore the correct operation of the siren.
2
STC/LED unbal-
ancing
Negative to
remove
NEGATIVE
TO GIVE
Positive to
remove
Positive to
give
Negative to
remove with
4k7 Ohm re-
sistance
N e g a t i v e
to give with
4k7 Ohm re-
sistance
-
-
The STC and LED inputs can be balanced to negative to give or to remove with or without 4k7 Ohm
resistance or to positive to give or to remove.
3
Alarm
encod-
ing
MAX. 5
IN 24
HOURS
Unlimited
-
-
-
-
-
-
•
Value 1: the siren blocks the functioning of the Cone and the Flash in rest status after 5 alarms in
within 24 hours and unblocks it after 24 hours from the first alarm
•
Value 2: the siren does not perform any blocking
4
Main
Sound
TONE 1
Tone 2
Tone 3
Tone 4
Tone 5
Tone 6
Tone 7
Tone 8
5
A l t e r n a t i v e
Sound
Tone 1
TONE 2
Tone 3
Tone 4
Tone 5
Tone 6
Tone 7
Tone 8
In steps 4 and 5 the selectable tones of the "Main Sound" (coupled to the SA control) and "Alternative
Sound" (based on the programming coupled to the LED control) passages are programmed. Once the
step is selected, the Modulation can be heard whenever the PB1 button is pushed.
6
FLASH
FLASH FOL-
LOWS THE
A L A R M
STATUS
40-minute
FLASH or
r e s t o r i n g
from STC
R e s t o r i n g
from STC
-
-
-
-
-
•
Value 1
: the Flash is restored at the rebalancing of the input that has generated the alarm
•
Value 2
: the Flash automatically deactivates after approximately 40 minutes or when the STC input
is rebalanced
•
Value 3
: the Flash is deactivated when the STC input is rebalanced
7
STC input
Red LED
FOLLOWS
STC
Change of
the status
with a Beep
Change of
status with
a Beep and
Red LED
Beep and
RED LED
are deacti-
vated
-
-
-
-
•
Value 1
: the RED LED is activated at the unbalancing of the STC input and is deactivated at the
rebalancing of the STC input
•
Value 2
: a BEEP signals both the unbalancing and the rebalancing of the STC input
•
Value 3
: the unbalancing of the STC input activates a BEEP and the RED LED, the rebalancing of
the STC input activates a BEEP and deactivates the RED LED
•
Value 4
: RED LED and BEEP are not activated by the unbalancing of the STC input
8
Enabling
None
a
t
a + t
v
a + v
T + V
a + t + v
Tampers
In this step, the tampers to activate or otherwise the
T T output
are enabled:
•
a
: anti-foam
t
: temperature
v
: anti-vibration
9
LED input
GREEN
LED DOES
NOT FOL-
LOW THE
STATUS
Alternative
sound to
the unbal-
ancing
Green
status and
Alternative
sound to
the unbal-
ancing LED
At the un-
balancing,
the red LED
repeats the
last signal-
ling
•
Value 1
: the unbalancing of the LED input activates the GREEN LED, the rebalancing of the LED
input deactivates the GREEN LED
•
Value 2
: the unbalancing of the LED input activates the alarm with the Alternative Sound and the
Flash. The rebalancing deactivates the Sound while the Flash behaves based on its configuration.
•
Value 3
: simultaneously executes the actions of Value 1 and 2
•
Value 4
: the unbalancing of the LED input activates the visualisation of the STC input status with
the RED LEDs
E
N
G