- 7 -
IST0649V1/0
H
1/2 D
1/2 D
D
D
TX/RX
TX/RX
TX/RX
D
D
1/2 D
1 mt
TX/RX
TX/RX
TX/RX
1/2 D
D
TX/RX
TX/RX
INSTALLATION RULES
The beam and the reflector must be installed on plane wall, not subject to vibrations or deformation.
Please keep in mind these basic rules:
-
In order to obtain total coverage,
the distance (D) between more
TX/RX couples must not
exceed 15 meters.
-
distance from the walls
must be about the half
of the distance between
two beams (1/2 D).
-
distance from the ceiling (H)
must be between min. 40 cm.
and max 1 meter.
-
check the possibility of installing
reflectors in axis with beams.
In case of inclination of the roof, install the first beam at about 1
meter from the highest wall and at H distance from the
ceiling.
Install other beams maintaining distance D
between them and distance H from the
ceiling.
Check to have max 1/2 D
distance between the beam
and the lowest side of the
wall from the ceiling.
Check that Receiver and
Transmitters can be
installed on the same axis.
In case of sloping roofs, install the first beam at H
distance from the highest side of the roof.
Install other beams maintaining distance D
between them and distance H from the ceiling.
Check to have the max distance of 1/2D
between the beam and the wall from the
lowest side of the roof.
Check that Receiver and
Transmitters can be installed on
the same axis.
H
Summary of Contents for BF100 A
Page 13: ...13 IST0649V1 0...
Page 14: ...14 IST0649V1 0...