background image

Hood/Trunk Pin Switch

1. Locate the vehicle hood or trunk pin switch that shows ground when the

hood or trunk is open only.

2. Connect the 

TAN

 wire to the vehicle hood or trunk switch wire.

3. If the vehicle does not have a hood or trunk switch, install a pin switch

and connect it to the 

TAN

 wire.

Siren

1. Choose a location in the engine compartment away from high heat engine 

components, moving parts and direct exposure to water.

2. Make sure the siren and siren wires cannot be seen or reached from

below the vehicle.

3. Mount the siren with the two self tapping screws to a solid metal surface.
4. Connect the siren 

BLACK

 wire to the alarm module 

VIOLET

 wire.

5. Connect the siren 

RED

 wire to the alarm module 

RED

 wire.

Power and Ground Connections

I

CAUTION

: Do not plug in the system fuses until the final step

below.

1. Connect the 

RED

 wire to one of the supplied fuse assemblies.

2. Connect the 

RED/WHITE

 wire to the other fuse assembly (if the vehicle

parking lights are (+) positive).

3. Connect the fuse assembly(s) to one of the supplied 10mm ring terminals.
4. Connect the 

BLACK

 wire to the other 10mm ring terminal.

5. Remove the (+) and (-) battery bolts. Do not disconnect the battery

clamps.

6. Connect the empty fuse assembly(s) to the positive battery post.
7. Connect the 

BLACK

 wire to the battery negative post.

8. Inspect all alarm wiring. Make sure all wires are connected.
9. Install the 5 amp fuse in the 

RED

 wire fuse assembly.

10. Install the 20 amp fuse in the 

RED/WHITE

 fuse assembly (if the vehicle

parking lights are positive).

13

Phoenix2 Rev. A - Installation Manual 0399

Summary of Contents for Phoenix 2

Page 1: ...Phownix2 Rev A Installation Manual Front Cover ...

Page 2: ......

Page 3: ...dicator 6 Ignition Input 6 Channel 2 Accessory Output 6 Channel 4 Accessory Output 6 Channel 6 Accessory Output 7 Parking Lights 7 Interior Light Trigger Illumination 7 Starter Disable 7 Door Lock Unlock 8 Door Lock Diagrams 9 Hood Trunk Pin Switch 13 Siren 13 Power and Ground Connections 13 Programmable Features 14 Programming Table for Alarm Features 15 Programming Table for Remote Controls 16 1...

Page 4: ...val of Prime Security could void the user s authority to operate this equipment 2 Phoenix2 Rev A Installation Manual 0399 Important Information Required Installation Tools Voltmeter Wire Strippers Electric Drill Bits Phillips Screw Driver Convoluted Tubing Solder Gun Wire Crimpers Shrink Tube or Electrical Tape Optional Recommended Procedures 1 Test all circuits with a voltmeter 2 Make all wiring ...

Page 5: ...Wiring Diagram 3 Phoenix2 Rev A Installation Manual 0399 ...

Page 6: ...Output 9 LIGHT GREEN Second Stage Unlock Output 10 BLACK Battery 11 RED WHITE Parking Light Polarity Input or Input Select 12 RED BLACK Parking Light Output 13 WHITE Interior Light Input 14 WHITE BLACK Door Trigger Polarity Select Input 15 GREEN BLACK Unlock Switch Side 16 GREEN WHITE Unlock Motor Side 17 GREEN RED Unlock Polarity or Input Select 18 BLUE BLACK Lock Switch Side 19 BLUE WHITE Lock M...

Page 7: ...lied securely fasten the impact sensor allowing access to the adjustment screws 5 Phoenix2 Rev A Installation Manual 0399 Installation Procedures Control Unit 1 Select a location under the dash that will allow you to use the tie wraps to securely fasten the control unit 2 Mount the control unit as high as possible to ensure maximum range 3 Do not mount the control unit near moving parts 4 Avoid ar...

Page 8: ...ltmeter to locate the one wire that shows 12 volts when the ignition key is in the ON CRANK and RUN positions and 0 volts when the ignition key is in the OFF position 2 Connect the PINK wire to the vehicle ignition wire Channel 2 Accessory Output The DARK BLUE wire provides a 0 75 second ground output when the alarm is disarmed only This is ideal for trunk release If the remote control button is c...

Page 9: ... input When the alarm is remotely disarmed the interior lights will turn on for 30 seconds or until the ignition key is turned ON The WHITE BLACK interior light supply wire serves two purposes It informs the alarm whether the door trigger polarity is positive or negative switching and provides a positive or negative supply for interior light illumination 1 Connect the WHITE wire to the vehicle doo...

Page 10: ...te arm disarm button again within 3 seconds and the passenger doors will unlock 8 Phoenix2 Rev A Installation Manual 0399 Normally Closed 1 Locate the ignition switch wireloom under the dashboard 2 Use a voltmeter to find the one wire that will show 12 volts while the ignition key is in the cranking cycle only This should be the starter solenoid wire 3 Cut the starter solenoid wire Test by trying ...

Page 11: ...9 Phoenix2 Rev A Installation Manual 0399 ...

Page 12: ...10 Phoenix2 Rev A Installation Manual 0399 ...

Page 13: ...11 Phoenix2 Rev A Installation Manual 0399 ...

Page 14: ...12 Phoenix2 Rev A Installation Manual 0399 ...

Page 15: ...ED wire to the alarm module RED wire Power and Ground Connections I CAUTION Do not plug in the system fuses until the final step below 1 Connect the RED wire to one of the supplied fuse assemblies 2 Connect the RED WHITE wire to the other fuse assembly if the vehicle parking lights are positive 3 Connect the fuse assembly s to one of the supplied 10mm ring terminals 4 Connect the BLACK wire to the...

Page 16: ...on solid red 2 Select the feature you wish to program from the Programming Table for System Features or the Programming Table for Remote Controls on pages 15 16 Note the number of chirps associated with that feature 3 Turn the ignition key to the ON position 4 Within 10 seconds begin flicking the valet switch on and off The siren will chirp once each time you flick the switch on then off 5 Continu...

Page 17: ...ds twice for 1 second Ignition Controlled Door Lock Unlock ON 9 Wait 3 seconds the siren will chirp once for Off twice for On Programmable 0 or 3 Second Delay for Ignition Controlled Door Lock 0 Seconds 10 Wait 3 seconds the siren will chirp once for 3 seconds twice for 0 seconds Normally Open Normally Closed Starter Disable Normally Closed 11 Wait 3 seconds the siren will chirp once for normally ...

Page 18: ...ton the siren will chirp 4 times Remote Controlled Valet ARM DISARM SILENT Buttsons 19 Press the ARM DISARM SILENT buttons the siren will chirp 5 times Channel 6 Remote Controlled Accessory Output ARM DISARM OPTION Buttons 20 Press the ARM DISARM OPTION buttons the siren will chirp 6 times Remote Controlled Sensor Bypass TRUNK OPTION Buttons 21 Press the TRUNK OPTION buttons the siren will chirp 7...

Page 19: ...Phoenix2 Rev A Installation Manual 0399 ...

Page 20: ... 1999 Avital Technologies Inc Part Number 32 1270 Rev A Phoenix2 Rev A Installation Manual 0399 ...

Page 21: ...Phoenix2 Rev A Installation Manual 0399 ...

Reviews: