Channel 5 Accessory
The
LIGHT BLUE
wire provides a 1 second ground output when the
C
and
D
buttons are pressed at the same time for 1-2 seconds. If the
C
and
D
buttons
are continually pressed, the output will stay at ground as long as the buttons
are held. This output can be used for optional accessories such as window
roll-up/down or any other accessory requiring a (-) activation.
Remote Start Armed Signal (-) Output
The
GRAY/BLACK
wire will provide a continual ground output for as long as
the vehicle is in the remote start mode. This output can be used for additional
ignition, starter or heater/AC relays.
Siren/Horn (-) Output (Remote Panic Capability)
The
VIOLET
wire will provide (-) output when the
C
button is pressed for 3-4
seconds. The (-) output can be programmed for a continual output when
adding an optional siren or a pulsed output when tapping into the vehicle (-)
horn wire. See the "Programming Table for System Features" on page 31.
Factory Alarm Disarm (-) Output
The
GRAY/WHITE
wire will provide a 1 second ground output when the
START button is pressed.
1 . Arm the vehicle factory alarm system.
2. Use a volt/ohmmeter to locate the one wire that will show ground only
when the driver door key cylinder is held in the unlock position.
NOTE: Most factory alarm/disarm wires will show 8-12 volts while
armed. A few vehicle disarm wires will rest at a neutral state while
armed. Regardless of type, both types will change to ground when the
key cylinder is turned to unlock.
3 . Connect the
GRAY/WHITE
wire to the factory alarm disarm wire.
Factory Alarm Rearm
The system incorporates the ability to rearm a vehicle's factory alarm system if
it is necessary to disarm the factory alarm in order to remote start the vehicle.
While in the remote start mode, if you were to remotely shut off the engine or
allow it to "time out," three seconds later the system will turn on the interior
lights for five seconds and activate the door locks for two seconds while the
interior lights are on.
There are type types of factory alarm systems and this procedure will allow
you to rearm either type.
10
AviStart 4501 Installation Manual - 0999
Summary of Contents for AVISTART 4501
Page 1: ...AviStart 4501 Installation Manual 0999 ...
Page 5: ...3 AviStart 4501 Installation Manual 0999 Main Wiring Diagram ...
Page 6: ...4 AviStart 4501 Installation Manual 0999 Satellite Relay Module Diagram ...
Page 19: ...17 AviStart 4501 Installation Manual 0999 ...
Page 20: ...18 AviStart 4501 Installation Manual 0999 ...
Page 21: ...19 AviStart 4501 Installation Manual 0999 ...