11
© 2009 Directed Electronics. All rights reserved.
H1/5
ORANGE
(-) GROUND WHEN LOCKED OUTPUT*
This wire supplies a (-)500 mA ground as long as the system is locked
and when the remote start is activated. (This feature can be turned off
by programming the anti-grind option Off). This output ceases as soon
as the system is unlocked. The GWA can be hooked up to an optional
starter kill/anti-grind relay control module, a voice module or any ac-
cessory that requires a ground when armed.
*Available only when adding a receiver (P/N 543
H
) and remote
(P/N 474
L
).
H1/6
BROWN
(-) HORN OUTPUT*
This wire supplies a (-) 200 mA output that can be used to honk the
vehicle horn. It outputs a single pulse when locking the doors with the
remote, and two pulses when unlocking with the remote. This wire also
outputs pulses for 30 seconds when Panic Mode is activated. If the
vehicle has a (+) horn circuit, an optional relay can be used to interface
with the system.
*Available only when adding a receiver (P/N 543
H
) and remote
(P/N 474
L
).