background image

12 

Battery Installation 

 

When the batteries get weak, the battery warning symbol appears

  . It is still possible to measure temperature. The batteries must be 

replaced. When the battery symbol flashes   

  and “Lo” appears 

in the display, the batteries must be replaced. If the batteries are too flat, 

then the thermometer will switch off automatically. 
NOTE: 

• It is recommended to remove the batteries if the unit will not be used 

for an extended period of time. 

• Please properly dispose of the batteries away from small children and 

heat. 

• Batteries must be disposed of in accordance with local environmental 

and institutional policies. 

• Do not use rechargeable batteries. 

 
1. Open the battery case by sliding off the cover on the back of the unit. 

2. Remove used battery. 

3. Replace with 

2 x 1.5V LR03(AAA) alkaline

 batteries in designated area. 

The larger part of the battery should be facing up. You should still be 

able to see the "+" sign when battery is installed. 

4. Slide the cover back on. Unit is ready for immediate use 

       

Dispose of used batteries in accordance with the applicable legal 

regulations. Never dispose of batteries in the normal household waste. 

 

 

Summary of Contents for TS46

Page 1: ... GmbH Schiffgraben 41 30175 Hannover Germany AViTA Corporation 9F No 78 Sec 1 Kwang Fu Rd San Chung Dist New Taipei City 24158 Taiwan Importer Distributor INSTRUCTION MANUAL Please read this instruction manual carefully before using your forehead thermometer ...

Page 2: ...splay 5 Measuring Body Temperature in the Ear 6 Measuring Body Temperature on the Forehead 7 Measuring Object Liquid Temperature 8 Setting C F and Date Time 9 LED Flashlight 10 Memory Function 11 Cleaning and Disinfecting 13 Error Codes 14 Technical Specification 15 EMC Tables 16 Explanation of Symbols 18 ...

Page 3: ...akes temperatures in seconds by measuring the heat generated by the ear canal on the forehead Type of Use Reuse Multiple patient multiple use Intended User The Patient is an intended operator Patient selection criteria Handicapped persons and children are the exception of handicapped persons and children need assistance by another person to use the device ...

Page 4: ...ning from outdoor 10 To protect the environment dispose of empty batteries at appropriate collection sites according to national or local regulations 11 Please use the thermometer solely for its intended purpose 12 There are no absolute body temperature standards Keep reliable records of your personal temperature to serve as a reference for judging a fever 13 Under any circumstances the temperatur...

Page 5: ...3 19 If you would require any assistance during setting up using or maintaining please contact the manufacturer 20 Avoid using the device near an operating cell phone or microwave oven ...

Page 6: ...4 Product Identification 1 Forehead Cover Cap 2 Power Ear Measure button 3 Memory button 4 Probe 5 LCD Display 6 LED Flashlight 7 SET button 8 Forehead Measure button 9 Battery Compartment Lid ...

Page 7: ...te 2 Time 3 Measurement in progress 4 Temperatuer unit 5 Temperatuer unit 6 Degree of temperature 7 Sound symbol 8 Low battery symbol 9 Memory symbol and sets of records 10 Object measurement 11 Ear measurement 12 Forehead measurement ...

Page 8: ...beep sounds to let you know the appliance is ready and followed by last temperature reading 3 Make sure that the sensor tip and also the ear canal are clean As the ear canal is slightly curved you have to pull the ear slightly up and backwards before inserting the sensor tip This is important so that the sensor tip can be pointed directly at the eardrum 4 Insert the sensor tip carefully and press ...

Page 9: ... let you know the appliance is ready and followed by last temperature reading 3 When the beep sounds to let you know the appliance is ready press the Power Measure button and maintain pressure 4 Place the probe on your temple Slide the probe across your forehead to the other temple and then release pressure on button to stop temperature taking You ll hear a beep and your temperature will come up o...

Page 10: ... or liquid maintaining a distance of 3 cm then take one press on Forehead Measurement button or Ear Measurement button to take a measurement never immerse in liquids 4 After the measurement process is complete there comes a short beep and the measured value appears on the display 5 Please note that the displayed temperature is the measured and not the adapted surface temperature It is not the same...

Page 11: ...short beeps In Standby mode the date and time are shown and is displayed Enter into Setting Under power on condition press Set button for 5 seconds to enter into setting mode C F When the unit blinking press the SET button to change the unit Press the Memory button can save and confirm the unit then goes to next setting Year When the year Icon blinking press the SET button to change the number Pre...

Page 12: ...e Memory button can save and confirm the minute then goes to end the setting loop End setting loop the display shows OFF and switches off automatically LED Flashlight 1 When the device is on press and hold the Memory button for 3 seconds and the flashlight will turn ON 2 Flashlight will automatically shut off after a few seconds or press any button to shut off it NOTE The LED flashlight is a built...

Page 13: ...mory Button then pass it again to show the last measurement accompanied by symbol 2 The mode symbol will appear with each measurement stored in memory to indicate whether a person or object temperature was taken 3 Each press of the same button recalls a previous measurement Memory Deletion Remove batteries memory will be cleared NOTE All the readings will be cleared no matter record in Human Mode ...

Page 14: ...spose of the batteries away from small children and heat Batteries must be disposed of in accordance with local environmental and institutional policies Do not use rechargeable batteries 1 Open the battery case by sliding off the cover on the back of the unit 2 Remove used battery 3 Replace with 2 x 1 5V LR03 AAA alkaline batteries in designated area The larger part of the battery should be facing...

Page 15: ...be and tip with an75 Ethanol or Isopropyl alcohol before and after each measurement Thermometer Use a soft dry cloth to clean thermometer body Never use abrasive cleaning agents thinners or benzene for cleaning Do not scratch the surface of the probe lens or the display Do not expose the thermometer to extreme temperatures humidity direct sunlight or shock ...

Page 16: ...an 43 C 109 4 F Operate the thermometer only between the specified temperature ranges If necessary clean the sensor tip In the event of a repeated error message contact your retailer or Customer Services The temperature measured is lower than 34 C 93 2 F The operating temperature is not in the range 15 C 40 C 59 F 104 F Operate the thermometer only between the specified temperature ranges ...

Page 17: ... 700 1060 hPa Storage Transportation environment 25 C 55 C 13 F 131 F with relative humidity up to 95 non condensing Atmospheric Pressure 700 1060 hPa Display resolution 0 1 C Power supply 2 x 1 5V LR03 AAA alkaline Auto switch off in 60 seconds without operation Memory 30 sets Weight approx 60 g without battery Dimensions approx 131 4 37 3 x 40 4 mm Typical Service Life 3 years Battery Shelf Life...

Page 18: ...onsidered and applied The equipment is suitable for use in the mentioned environments when directly connected to the Public Mains Network b The test is not applicable in this environment unless the ME EQUIPMENT and ME SYSTEM used will be connected to the PUBLIC MAINS NETWORK and the power input is otherwise within the scope of the Basic EMC standard Guidance and manufacturer s declaration Electrom...

Page 19: ...ncy magnetic fields IEC 61000 4 8 30 A m c 50 Hz or 60 Hz a The equipment is suitable for use in Home Health Environments and Professional Health Care Environments limited to patient rooms and respiratory treatment facilities in hospital or clinics The more restrictive IMMUNITY acceptance limits have been considered and applied b Before modulation is applied c This test level assumes a minimum dis...

Page 20: ...tified Body This denotes the compliance of European Medical Device Directive 93 42 EEC Medical Device Manufacturer Authorized representative in the European Community Date of manufacture YYYY MM DD or YYYY MM Batch code YYMMWWWW Serial number YYMWWWXXXXX Keep dry Temperature limit ...

Page 21: ...hority WEEE 2012 19 EU Directives RoHS This product fulfilling the requirements of the RoHS Directive 2011 65 EU REACH This product fulfilling the requirements of the REACH Directive EC 1907 2006 and its amendments do not contain Substances of Very High Concern in concentration above the limit of 0 1 No substance s is are present in the parts of the product above the concentration of 0 1 weight by...

Page 22: ...er and against vertically falling water drops when enclosure tiled up to 15 The empty completely flat batteries must be disposed of through specially designated collection boxes recycling points or electronics retailers You are legally required to dispose of the batteries Importer Distributor Model Number Country of Manufacturer Unique Device Identifier TS46P 22113AV 2022 04 22 ...

Reviews: