TOC – Top Of Car Version 453 011AU
COP - Car Operating Panel Version 453 000AU
1. Using the screws provided, install the Memcom
+
unit
to the top of the lift car. The rubber feet must not be
removed as this can create feedback.
2. Connect the telephone line, the lift alarm push button
and any required accessories as per the wiring diagrams
shown on Page 4 of this guide.
3. The Memcom
+
TOC 4m external microphone will need
installing into the COP or to a high position in the car, such
as in a false ceiling or air vent. It may be necessary to test
the optimum microphone location.
4. Always connect the earth first before applying
90-230VAC
Earthing not required for 24VDC operation. Connect 0VDC
connection first if 24VDC supply is not turned off.
1. Install the Memcom
+
Unit to the back of the lift car
operating panel in advance.
2. Connect the telephone line, the lift alarm push button
and any accessories required.
3. Earthing not required for 24VDC operation. Connect
0VDC connection first if 24VDC supply is not turned off.
2