8
3. Quick Setup
3.1 Setup & Configuration - Lift Controller - Serial (E-Motive 4-Wire)
3.1.1 Encoder/Converter Board Wiring and Setup
To show lift position and status information on the ATOM, an E-Motive encoder is required. The CX-BASIC
is E-Motive’s standard encoder providing a single serial data connection to the ATOM display via 4-wire
connection. Power to the CX-BASIC can be supplied directly from the Display without the need for a seperate
power supply.
The following shows how to connect the CX-BASIC encoder into the ATOM display.
P1 P2 DR DO D/N
1 2 3 4 5 6 7 8 R1
PO
W
OU
T
+5
GN
D
+12
G
ND
EM
D
DR
D
P
1 P
2 D
R D
O D
/N
P1
P2
R6
PO
W
IN
P2
P
1
1.
Connect data & data return
wiring for the 4-wire serial
output (JP9 SER1) on the CX-
BASIC
2.
Ensure the screen is mounted
correctly within the fixture
3.
Screw in the power and ground
wiring to the ATOM Display. The
input is 12~24V DC and dual-
polarity.
4.
Connect data & data return to
EMD serial communication on
the display from the CX-BASIC
(JP9 SER1). Screw in the power
wiring for the CX-BASIC from
the display 12V DC output,
taking care to follow the correct
pin arrangement
5.
Connect power wiring from 12V
DC output to P1 & P2 on the
CX-BASIC Encoder Board.
6.
Ensure VCAN & EOL Switches
are “OFF”, and Serial data is set
to “E-Motive 4 Wire” in the on-
board menu.
Before
You start
Mechanical
installation
Quick setup
guide
Wiring and
connections
Network
overview
Technical