1. At the top-left corner of the application window, click

to open the New Task menu.

2. From New Task menu, click

.

3. In the Setup tab, click

.

4. In the following dialog box, select the administrator user name and click

.

5. Click

Change Password...

.

6. In the following dialog box, enter a new password and then confirm the new password.

7. Click

OK

.

Tip:

If you forget the default administrator password, resetting the password requires restoring the factory

default settings on every server in the site. To avoid this issue, it is highly recommended that you create at least
one other administrator level user as a backup.

Connecting Cameras to the Avigilon Control Center System

After all the cameras in your system have been physically connected to the ACC ES Analytics
Appliancenetwork, you need to connect the cameras to the ACC system so that video can be recorded and
indexed for search.

1. In the site Setup tab, click

.

The Connect/Disconnect Cameras... tab is displayed.

2. In the Discovered Cameras area, select one or more devices then click

Connect...

.

Tip:

You can also drag the device to a server on the Connected Cameras list.

3. In the Connect Camera dialog box, select the server you want the device to connect to.

NOTE:

If you are connecting multiple devices, all the cameras must use the same connection settings.

4. If you are connecting a third-party device, you may choose to connect the device by its native driver. In

the

Camera Type:

drop down list, select the device's brand name. If there is only one option in the drop

down list, the system only supports one type of driver from the device.

5. If the camera supports a secure connection, the

Camera Control:

drop down list is displayed. Select one

of the following options:

NOTE:

The setting may not be displayed if the camera only supports one of the options.

l

Secure

— The system will protect and secure the camera's configuration and login details. This

option is selected by default.

l

Unsecure

— The camera's configuration and login details will not be secured and may be

accessible to users with unauthorized access.

Cameras with a secure connection are identified with the

icon in the Status column.

Connecting Cameras to the Avigilon Control Center System

10

Summary of Contents for HD-NVRWS3-8TB

Page 1: ...User Guide Avigilon Network Video Recorder Workstation HD NVRWS3 8TB...

Page 2: ...trademark patent or other intellectual property rights of Avigilon Corporation or its licensors This document has been compiled and published covering the latest product descriptions and specificatio...

Page 3: ...Client Software 8 Starting Up the Client Software 8 Shutting Down the Client Software 8 Logging Into and Out of a Site 9 Logging In 9 Logging Out 9 Changing the Administrator Password 9 Connecting Cam...

Page 4: ...y existing Avigilon surveillance system or act as the base of a new site Overview Front View 1 Power button Controls the power supply to the recorder For more information see Power Status Indicator on...

Page 5: ...onnection 2 USB connectors Accepts USB connections to external devices 3 Headphone connector Accepts a line out audio connector 4 Microphone connector Accepts a line in audio connector 5 DVI connector...

Page 6: ...8 Padlock ring Allows a padlock to secure the computer cover to the chasis 9 DisplayPort connector Accepts a DisplayPort DP connection to a display monitor BackView 3...

Page 7: ...s DP l Connect monitor 1 directly to DP l Connect monitor 2 to monitor 1 in a daisy chain configuration DVI l Connect monitor 1 directly to DVI port l Connect monitor 2 to DP using DP to DVI adapter H...

Page 8: ...nter software license wizard Other parts of the ACC system may start while you perform this procedure but you will not be able to use any of the features until after license activation is complete 1 C...

Page 9: ...tes from Avigilon then click Register 11 Find the downloaded license file and copy the file to the recorder 12 If the Activation File Saved message is still displayed in the Add License wizard click N...

Page 10: ...kstation acquires an IP address on the network through DHCP If you need to set up the recorder to use a static IP address or any specific network configuration see the Windows Help and Support files f...

Page 11: ...Up and Shutting Down the Avigilon Control Center Client Software The ACC Client software should start automatically when Windows starts Refer to the following steps if it doesn t Starting Up the Clie...

Page 12: ...ite 3 Enter your username and password for the selected sites 4 Click Log In You are logged into the selected sites If you want to be notified when new or disconnected sites come online select the Not...

Page 13: ...ne or more devices then click Connect Tip You can also drag the device to a server on the Connected Cameras list 3 In the Connect Camera dialog box select the server you want the device to connect to...

Page 14: ...ure if you prefer to keep the default settings Before you can assign a recording schedule you must create a template The template allows you to assign the same schedule to multiple cameras Creating a...

Page 15: ...video is kept so that you have the best quality video when you need it The amount of data aging that is available depends on the camera you have connected to your system l For JPEG2000 or JPEG compres...

Page 16: ...op down list for each camera NOTE If the time estimated in the Total Record Time column is significantly shorter than what is set in the Max Record Time column the camera s actual recording time will...

Page 17: ...a user in the Search field to locate specific users c Click Add The users are added to the Members list 6 Click OK to save the new group Adding Users 1 In the site Setup tab click 2 In the Users tab c...

Page 18: ...erarchy l If you are setting up an enterprise system that includes large physically dispersed sites you can use the Corporate Hierarchy feature to define system access at different levels of the organ...

Page 19: ...off Flashing white Power is being supplied and the recorder is in sleep state Flashing green There is a known problem with the power supply unit Steady green There is an unknown problem with the power...

Page 20: ...z auto switching Power Consumption 290 W Power Supply Single non redundant Environmental Operating Temperature 5 C to 35 C 41 F to 95 F Storage Temperature 40 C to 65 C 40 F to 149 F Humidity 20 to 80...

Page 21: ...Avigilon warranty terms for this product is provided at avigilon com warranty Warranty service and technical support can be obtained by contacting Avigilon Technical Support avigilon com contact us Li...

Reviews: