9. Push the cable through the grommet in the rear cover plate. If using external power or I/O then pull the
tabs out of the grommets and feed the wires through the smaller grommet holes. Silicone sealant is
recommended to seal any wires in the smaller grommet holes. Install the RJ-45 connector to the ends of
the cable. If using external power or I/O then install the provided terminal blocks onto the wires.
Installing the Surface Mount with a Rear Conduit
Important:
Conduit installations only support a 1/2" conduit.
NOTE:
The following procedure uses a conduit with a bare end. If a conduit with a nut on the end is used, fasten
the conduit to the surface mount adapter using the nut after you have connected the conduit to the surface
mount.
If installing surface mount with a rear cable conduit (not provided):
1. Pull cables through the conduit.
2. Place the mounting template on the mounting surface so the conduit aligns with the through wall cable
hole marked on the mounting template.
3. Use the mounting template to drill 4 holes in the correct locations and install the screw anchors.
Installing the Surface Mount with a Rear Conduit