Safety 

– CAUTION 

  This UPS utilizes voltages that may be hazardous. Do not attempt to 

disassemble  the  unit.  The  unit  contains  no  user  serviceable  parts. 
Only factory service personnel may perform repairs.   

  Internal battery voltage is 12Vdc. sealed, lead-acid, 6 cells battery. 

  Connection  to  any  other  type  of  receptacle  other  than  a  two-pole, 

three-wire grounded receptacle may result in shock hazard as well as 
violate local electrical codes. 

  In the event of an emergency, press the OFF button and disconnect 

the  power  cord  from  the  AC  power  supply  to  properly  disable  the 
UPS. 

  Do not allow liquids or any foreign object to enter the UPS. Do not 

place beverages or any other liquid-containing vessels on or near the 
unit.   

  This unit intended for installation in a controlled environment 

(temperature controlled, indoor area free of conductive contaminants). 
Avoid installing the UPS in locations where there is standing or 
running water, or excessive humidity. 

  Do not plug the UPS input into its own output. 

  Do not attach a power strip or surge suppressor to the UPS. 

  Do not attach non-computer-related items, such as medical 

equipment, life-support equipment, microwave ovens, or vacuum 
cleaners to UPS 

 

To reduce the risk of overheating the UPS, do not cover the UPS’ 
cooling vents and avoid exposing the unit to direct sunlight or 
installing the unit near heat emitting appliances such as space 
heaters or furnaces. 

  Unplug the UPS prior to cleaning and do not use liquid or spray 

detergent. 

  Do not dispose of batteries in a fire as they may explode. 

  Do not open or mutilate the battery or batteries.    Released 

electrolyte is harmful to the skin and eyes.    It may be toxic. 

  A battery can present a risk of electrical shock and high short circuit 

current.  The  following  precautions  should  be  observed  when 
working on batteries: 

1)  Remove watches, rings, or other metal objects from the hands. 
2)  Use tools with insulated handles. 
3)  Wear rubber gloves and boots. 
4)  Do not lay tools or metal parts on top of batteries. 

Summary of Contents for PRO 600VA

Page 1: ...Aviem Pro User s Manual AVIEM PRO 600VA 800VA Uninterruptible Power System ...

Page 2: ...ere is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to ...

Page 3: ...tage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible INTRODUCTION This UPS is specially designed for Personal Computer with multi fu...

Page 4: ...power failure back up time is shorten 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Mains normal but LED is flashing Power cord is loose Reconnect the power cord properly If any abnormal situatio...

Page 5: ... return it to the place of purchase 2 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load no electrical devices such as computer...

Page 6: ...contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS away from the monitor at least 20cm to avoid interference 20CM 4 Connection Plug the UPS into a 2 pole 3 wire grounded receptacle Then connect one computer related device into each of the power receptacles supplied on the back of the UPS ...

Page 7: ... Start All Aviem Pro Series are equipped with DC Start To start the UPS when AC utility power is not available simply press the power switch 7 Green Power Function All Aviem Pro UPS is equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on inverter mode ...

Page 8: ...ge Time 6 hours to 90 after complete discharge TRANSFER TIME Typical 2 6 ms typical 10ms max INDICATOR AC Mode Green LED lighting Battery Mode Green LED Flashing AUDIBLE ALARM Backup Mode Sounding every 10 seconds Low Battery Sounding every 1second Overload Sounding every 0 5 second Fault Continuously sounding PROTECTION Full Protection Discharge overcharge and overload protection PHYSICAL Dimensi...

Reviews: