5) Disconnect charging source prior to connecting or disconnecting
batteries terminals.
Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required precautions.
Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and type of
sealed lead-acid battery. The maximum ambient temperature rating is
40
℃
.
This pluggable type An equipment with battery already installed by
the supplier is operator installable and may be operated by laymen.
During the installation of this equipment it should be assured that the
sum of the leakage currents of the UPS and the connected loads
does not exceed 3.5mA.
Attention, hazardous through electric shock. Also with disconnection
of this unit from the mains, hazardous voltage still may be accessible
through supply from battery. The battery supply should be therefore
disconnected in the plus and minus pole of the battery when
maintenance or service work inside the UPS is necessary.
The mains socket outlet that supplies the UPS shall be installed near
the UPS and shall be easily accessible.
INTRODUCTION
This UPS is specially designed for Personal Computer with
multi-functions. Its light weight, compact design perfect fits to the
limited working environment. The line of UPS is equipped with boost
and buck AVR to stabilize input voltage range. It is also built-in with DC
start function. This function enables the UPS to be started up without
AC power supplied. Although it’s a small UPS, The main features of
Aviem Pro UPS are listed below:
Microprocessor control guarantees high reliability.
Equipped with Boost and Buck AVR.
Green Power Function for energy saving.
DC Start Function.
Auto restart while AC recovery.
Compact size, Light Weight.
Provides AC Overload protection.