background image

5)  Disconnect  charging  source  prior  to  connecting  or  disconnecting 

batteries terminals. 

  Servicing  of  batteries  should  be  performed  or  supervised  by 

personnel  knowledgeable  of  batteries  and  the  required  precautions.   
Keep unauthorized personnel away from batteries. 

  When replacing batteries, replace with the same number and type of 

sealed lead-acid battery. The maximum ambient temperature rating is 
40

  This  pluggable  type  An  equipment  with  battery  already  installed  by 

the supplier is operator installable and may be operated by laymen. 

  During the installation of this equipment it should be assured that the 

sum  of  the  leakage  currents  of  the  UPS  and  the  connected  loads 
does not exceed 3.5mA. 

  Attention, hazardous through electric shock. Also with disconnection 

of this unit from the mains, hazardous voltage still may be accessible 
through supply from  battery.  The  battery supply  should be therefore 
disconnected  in  the  plus  and  minus  pole  of  the  battery  when 
maintenance or service work inside the UPS is necessary. 

  The mains socket outlet that supplies the UPS shall be installed near 

the UPS and shall be easily accessible. 

 

INTRODUCTION 

This  UPS  is  specially  designed  for  Personal  Computer  with 
multi-functions.    Its  light  weight,  compact  design  perfect  fits  to  the 
limited  working  environment.    The  line  of  UPS  is  equipped  with  boost 
and buck AVR to stabilize input voltage range.    It is also built-in with DC 
start  function.    This  function  enables the  UPS to  be  started  up  without 
AC  power  supplied.  Although  it’s  a  small  UPS,  The  main  features  of 
Aviem Pro UPS are listed below: 

 

Microprocessor control guarantees high reliability. 

 

Equipped with Boost and Buck AVR. 

 

Green Power Function for energy saving. 

 

DC Start Function. 

 

Auto restart while AC recovery. 

 

Compact size, Light Weight. 

 

Provides AC Overload protection. 

 

Summary of Contents for PRO 600VA

Page 1: ...Aviem Pro User s Manual AVIEM PRO 600VA 800VA Uninterruptible Power System ...

Page 2: ...ere is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to ...

Page 3: ...tage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible INTRODUCTION This UPS is specially designed for Personal Computer with multi fu...

Page 4: ...power failure back up time is shorten 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Mains normal but LED is flashing Power cord is loose Reconnect the power cord properly If any abnormal situatio...

Page 5: ... return it to the place of purchase 2 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load no electrical devices such as computer...

Page 6: ...contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS away from the monitor at least 20cm to avoid interference 20CM 4 Connection Plug the UPS into a 2 pole 3 wire grounded receptacle Then connect one computer related device into each of the power receptacles supplied on the back of the UPS ...

Page 7: ... Start All Aviem Pro Series are equipped with DC Start To start the UPS when AC utility power is not available simply press the power switch 7 Green Power Function All Aviem Pro UPS is equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on inverter mode ...

Page 8: ...ge Time 6 hours to 90 after complete discharge TRANSFER TIME Typical 2 6 ms typical 10ms max INDICATOR AC Mode Green LED lighting Battery Mode Green LED Flashing AUDIBLE ALARM Backup Mode Sounding every 10 seconds Low Battery Sounding every 1second Overload Sounding every 0 5 second Fault Continuously sounding PROTECTION Full Protection Discharge overcharge and overload protection PHYSICAL Dimensi...

Reviews: