![Avidyne FlightMax EX500 Installation Manual Download Page 67](http://html.mh-extra.com/html/avidyne/flightmax-ex500/flightmax-ex500_installation-manual_3031543067.webp)
Installation Manual
P/N 600-00175-000 Rev 04
MFD Feature Setup and Checkout
- 57 -
4.
Set the tilt table to 10
o
roll right. The value should be 10.0R ±1.0
o
. If the value is out of range,
repeat step R.
5.
Set the tilt table to 10
o
roll left. The value should be 10.0L ±1.0
o
. If the value is out of range,
repeat step R.
6.
Set the tilt table to 0
o
roll. The value should be 0.0 ±1.0
o
.
7.
Proceed to step S.
S.
Save Configuration
1.
Adjust the GAIN controls for a GAIN POT /2 setting to 4- or 5-.
2.
The FAULTS field will display GYRO.
3.
Set the TILT SETTING to 15.0D. The fault fields will flash indicating that your settings are
being saved. If the save procedure is successful, the GYRO fault will disappear and the
azimuth count will cycle through its entire number range.
4.
If the GYRO fault remains, set TILT to 0 and repeat step 3.
5.
After saving the configuration, this section is complete.
Bendix/King Replacement Sections END
5.9.6 Radar Checkout
Perform a functional test of the RADAR system in accordance with manufacturers instructions. See the
Avidyne
EX500/EX600
MFD Pilot Guide
for display operation.
Summary of Contents for FlightMax EX500
Page 1: ...Release 3 and Later Installation Manual 700 00007 700 00167 P N 600 00175 000 Rev 04 ...
Page 2: ......
Page 90: ...Installation Manual Service P N 600 00175 000 Rev 04 80 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 92: ...Installation Manual Service P N 600 00175 000 Rev 04 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 122: ...Installation Manual P N 600 00175 000 Rev 04 112 This page intentionally left blank ...
Page 123: ......