Chapter 1: Overview
1
Chapter 1: Overview
Each VENUE D-Show
®
Sidecar adds 16 input channels to the
VENUE D-Show Main unit console.
A total of three Sidecars can be connected to the D-Show Main
unit, for a maximum of 56 Input Channel faders.
Components
Included Components
The following components are included with a Sidecar:
• Sidecar unit
• Console Link cable
• 2 AC power cords
• Set of Hex wrenches for attaching the Sidecar
Operational Requirements
Temperature and Ventilation
VENUE components should be operated away from heat
sources and with adequate ventilation.
Storage
VENUE components should be stored and transported at tem-
peratures not lower than 0 degrees F (–18 degrees C) and not
exceeding 140 degrees F (60 degrees C).
Operation
VENUE components should be operated at temperatures not
lower than 40 degrees F (4 degrees C) and not exceeding
115 degrees F (46 degrees C).
Water and Moisture
VENUE components should be operated away from sources of
direct moisture and should be kept clear of liquids that might
spill into the units. If condensation is present on a unit, leave
the unit to dry in ambient air for at least one hour before pow-
ering the unit on.
Cleaning and Maintenance
If you need to clean the surface of any VENUE component, use
a dry cloth. Do not apply any cleaning solutions, spray clean-
ers, or abrasives to the surface.
Power Connections
Each power supply in the Sidecar requires its own power con-
nection. Each power supply is auto voltage-selecting (100V to
240V). A modular IEC power cable is provided for each power
supply in the unit.