background image

8

. Maintenance

Make sure to turn off the power supply before maintenance. In order to avoid 
electric shock, non-professionals are not allowed to disassemble the device.

1. Clean Outer Cover

·

The static electricity can cause dust accumulation. Please clean the outside of 
the outer covery in time and recommended to clean it at least once a month.

·

Disconnect the power supply, wipe it with clean, soft and moist sponges. 
Don’t immerse this device into water or any other liquid and prevent the risk 
from liquid into engine case. 

·

Don’t clean any part of the device with abrasive, corrosive or flammable 
cleaners such as cleanser, alkaline detergent, diluent, bleach, alcohol, 
gasoline or organic solvents.

2. Replace the Filter

·

Depending on the degree of contamination of the actual application 
environment, the shelf life of each filter will be different. If the PM2.5 value on 
display screen is very high and decreases extremely slow, or the filter has an 
unusual smell, please clean or replace the filter in time. 

·

The shelf life of filter is 3000 hours. When detecting filter needs to be 
replaced, The filter replacement mark “    ” will be displayed on display screen 
of main unit.

·

The filter can not be washed. The vacuum cleaner or brush can be used to 
clean PM2.5 and larger particles, and then take the filter to a strong sun 
exposure. Part of the performance of filter can be restored. The filter can be 
obtained at appointed dealers. 

·

When replacing the filter, screw and open bottom cover according to arrow 
instruction and turn back bottom cover after filter replacement.

·

Recommend users clean the filter at least once a month. After long-time wet 
weather, please remove the filter in time to clean and expose under the sun to 
avoid failure of filter.

3. Clean the Power Plug

·

Check the power plug regularly. The power plug is easy to accumulate dust 
and can cause poor insulation by moisture. In such case, remember to pull out 

Summary of Contents for C2

Page 1: ...Thank you for choosing UV Air Purifier C2 Please read this User Manual carefully before use and maintenance and keep it properly for future reference User Manual Version 1 1 Air Purifier Model C2 ...

Page 2: ......

Page 3: ...1 Table of Contents I Device and Accessories Ⅱ Product Introduction Ⅲ Quick Use Guide Ⅳ Maintenance Ⅴ Safety Instructions Ⅵ Troubleshooting Guide Ⅶ After sales Service and Warranty Card 2 3 6 8 9 11 12 ...

Page 4: ...ure 1 in the package If any shortage or damage Please contact suppliers or manufacturer immediately Figure 1 Packing List Main Unit including Filter x 1 User Manual including Warranty Card x 1 Thank you for choosing UV Air Purifier C2 Please read this User Manual carefully before use and maintenance and keep it properly for future reference User Manual Version 1 0 Air Purifier Model C2 ...

Page 5: ... antibacteria mites killing deodorant insect prevention and UV Protection The super fine hole structure of Bamboo fiber make it have strong absorption and can absorb formaldehyde benzene methylbenzene ammonia and remove odor b HEPA Filter Purification 99 9 of the microscopic particles 0 3 microns and larger can be captured while pass through the HEPA filter It is highly efficient at tobacco smoke ...

Page 6: ...ization Photocatalytic Degradation HEPA Filter Bamboo Fiber Bamboo Charcoal Eco friendly Filter Air Quality Grade Good Moderate Color Indicator Green Blue Yellow Red Filters Filter Weight 1 65kg 155mm Inner Dia 260mm outer Dia 300mm H Body Material ABS Aplicable Space 36 62 3m2 Purification Efficiency Super grade ηPM 7 2 m3 W h Super grade ηHCHO 3 m3 W h CADRPM 519 5m3 h CADRHCHO CCMPM P4 F4 CCMHC...

Page 7: ...tion Outlet Inlet Product Main Body Figure 2 1 Top Cover Figure 2 4 Bottom Figure 2 2 Top View of Display Screen Figure 2 3 Air Quality Indicator Anti slip Pads 2 Product Parts Introduction Bottom Cover Speed Sleep Timer ON OFF Auto UV ...

Page 8: ...lay Screen Display Screen Area Filter Replacement Indicator It will display when need to repalce filter meantime PM2 5 Value Display Air quality indicator will display different colors according to different PM2 5 value of room air Details as following figure 0 35 75 115 Good Moderate 500 Criteria Range µg m Air Quality Indicator Fan Speed Display Area Unhealthey Very Unhealthey Speed Sleep Timer ...

Page 9: ... real time indoor air quality Note In the Auto mode short press the Speed button or Sleep button on the control panel to automatically exit Auto mode 2 4 UV Sterilization Short press the UV button on the control panel to turn on off the UV sterilization function when the main unit is turned on The UV button will be lit when the UV sterilization is turned on 2 5 Sleep Button Press the Sleep mode on...

Page 10: ...2 5 value on display screen is very high and decreases extremely slow or the filter has an unusual smell please clean or replace the filter in time The shelf life of filter is 3000 hours When detecting filter needs to be replaced The filter replacement mark will be displayed on display screen of main unit The filter can not be washed The vacuum cleaner or brush can be used to clean PM2 5 and large...

Page 11: ...place directly under the air container to avoid the condensation water to drop into the product Don not place directly in places of oil flammble gases or possible leakage places to avoid potential fire causes by those being absorbed into the product Do not place this device in an environment with heat fire moisture large dust and abnormal temperature to avoid power leakage to cause fire and electr...

Page 12: ...ealth Don t put liquid or foreign substances to avoid any injury or damage 4 2 Power Cord and Power Plug a Power Plug Stop tousle and unplug the power cord immediately in the following cases to avoid electric shock fire or smoke Device stops running when power cord is moving Malfunction of any control button The power cord or power plug is abnormally hot There is burning smell Abnormal sound or vi...

Page 13: ...e or release odor due to adsorption of contaminants The location of main unit may not be reasonable and cause device not easy to inhale air pollutants Check if detection port of sensor is blocked Change the position of the device Clean detection port Check whether the doors and windows are closed or whether there is a source of pollutants in room Check the filter is workable Remove and handle the ...

Page 14: ...by the users enters into the device to cause abnormal operation c Trouble caused by unauthorized demolition repair or transformation of device d Trouble caused by accidental falling down in use or handling e Trouble caused by the failure to operate in accordance with the correct operations in user manual f The damage caused by unpredictable natural disasters such as fire earthquakes floods etc Fro...

Page 15: ......

Page 16: ......