Figure 5- 3 Control Interface of CommWatch
Set the parameters (baud rate, data bit, stop bit and parity bit) correctly to ensure
reliable RS232 control.
5.2.3 RS232 Communication Commands
1) Case-sensitive.
2) “[“, “]” in the commands are for easy recognition only and not necessary in real
operations. Other symbols including “.”, “,”, “/”, “%”, “;”, “^”. are parts of the
commands.
3) Feedbacks listed in the column “Feedback Example” is only for reference,
feedbacks may vary according to different operations.
4) Dial the EDID switcher to “1111” before sending commands pertaining to software
EDID management (with grey background). Refer to 4.4 EDID Management for
detailed information.
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
Command
Function
Feedback
Example
System Commands
/%Lock;
Lock the front panel buttons.
System Locked!
/%Unlock;
Unlock the front panel buttons.
System Unlock!
/^Version;
Query the firmware version
VX.X.X
/:MessageOff;
Turn off command feedback from
the com port. It will only show
/:MessageOff;
Parameter
Monitoring area,
indicates whether
the command sent
Command