![AVGear AVG-MS44 User Manual Download Page 14](http://html.mh-extra.com/html/avgear/avg-ms44/avg-ms44_user-manual_3030933014.webp)
AVG-MS44
EDIDUpgrade[x].
Upgrade EDID data via the
RS232 port
[X] is for input port, when the
value of X is 5, it means to
upgrade to all input ports.
When the switcher gets the
command, it will show a
message to send EDID file
(.bin file). Operations will be
cancelled after 10 seconds.
(Note 1) Please cut off all
connections of HDBaseT
ports.
Please send the EDID file
UpgradeIntEDID[x].
Select one type of EDID data
and upgrade built-in EDID
data. Supports 4 types of
EDID data:
1. 1080P, 2D, PCM2.0
2. 1080P, 2D, 5.1 (audio)
3. 1080P, 3D, PCM2.0
4. 1080P, 3D, 5.1 (audio)
[x] = 1, 2, 3 or 4
When the switcher gets the
command, it will show a
message to send EDID file
(.bin file). Operations will be
cancelled after 10 seconds.
Please send the EDID file
EDID/[x]/[y].
Set the built-in EDID data of
input port [x] to type [y].
The value of [y] is 1, 2, 3,
and 4. The EDID data types
are same as mentioned
above.
EDID/02/01
Note:
1. Please disconnect all the twisted pairs before sending command EDIDUpgrade[X].
2. In the above commands, “[”and “]” are symbols to aid reading and do not need to
be typed in actual operation.
3. Please remember to end the commands with the end symbols “.” or “;”.
4. Type the command carefully, it is case-sensitive.
Summary of Contents for AVG-MS44