32
ZM505 Indicator User Instructions
Supervisor menu
6 Supervisor menu
The Supervisor menu allows the setup and editing of the Preset Tare register and the
accumulation application parameters. The tare portion of the menu appears only if
Preset Tare is enabled. Refer to the Service manual.
To access the Supervisor menu enter the
Supervisor password, 1793
. The ZM505
has a Preset Tare register memory which can store 10 tares.
Figure 6.1 Supervisor menu
Press and hold the
SETUP
key until the password entry screen appears. Enter the
Supervisor password, 1793 and press the
ZERO
key.
Highlight the item you wish to set and press the
Enter
key. The definitions of each item
in the Supervisor menu are described below.
SuPEr
This is the top item in the Supervisor menu.
tArE
This item appears only if Preset Tares are enabled. Use this to enter tare
weights for up to 10 Preset Tares.
Edit
Use this to set the tare weight for Tare 1 through Tare 10.
Use this to print the tare list to your desired port or to the USB port.
See
Printed Preset Tare report example on page 33
rESEt
Use this to clear all tares in memory.
AccuM
Use this item to set the accumulation paramaters below.
Super
Tare
Edit
Tare 1
Tare 10
Accum
Prt tot
Tot Fmt
Clr tot
Off
On
Port 1
Port 2
USB
Reset
Yes
No
Enter
tare
weight
…
Port 1
Port 2
USB
Reset
Yes
No
Key in
Format #
Off
On
Appears only if Preset Tare
is enabled.
If the Preset Tare list has been reset and you print the Preset Tare report the 10