1.8.1 Alternative Power Supply Arrangements

The ZG310 is designed to be operated from a 9V to 36V voltage source that is capable 
of supplying the primary power for the printer.  

The electrical specification for the power supply input of the ZG310 printer is: 

The average and peak current requirements can be adjusted by firmware control 
codes. See the Service Manual for details.

The recommended power supply input is either a 12V or 24V vehicle battery, this allows 
the printer to perform at its best. However, the printer will automatically accommodate 
any DC input voltage in the range 9V to 36V. In addition, power supplies with lower 
current capacities may be accommodated by varying the internal Power Save 
parameter.  See the Service Manual or contact the factory for more details.

The recommended power supply input is either a 12V or 24V vehicle battery, this allows 
the printer to perform at its best. However, the printer will automatically accommodate 
any DC input voltage in the range 9V to 36V.  

1.9 Printer Firmware Revisions

The manufacturer reserves the right to modify and improve the firmware in its printer 
products at any time. Every effort is made to ensure backward compatibility, however, 
no guarantee in this respect is given or implied.

The ZG310 includes a flash-reprogrammable microcontroller. This allows firmware 
upgrades under customer control (including customized fonts, which may be created 
using the Font Editor Utility). Refer to the factory for more information in this feature, if 
required.

1.10 Copyright Notice and Disclaimer

Copyright subsists in the manufacturer's intellectual property, including controller 
firmware (embedded software) and circuit diagrams, pin connection lists and 
application data. No warranty in respect of patent rights of the manufacturer or of third 
parties is given. Unauthorized reproduction or amendment of controller firmware may 
result in prosecution.

Fujitsu is a registered mark of its owner Fujitsu Limited. References to this or other 
owners' marks in this document are for illustrative purposes only.  

The manufacturer does not assume responsibility for interchangeable functionality of 
other parties' command sets.

Input Voltage Range:

+9V to +36V

internal over voltage at 37V and reversal protection

Supply Current Requirement:

50mA

Printer in Idle Mode

( typical @24V in )

1A average

Printer Printing

 

4A peak

Printer Printing

Summary of Contents for ZG310

Page 1: ...ZG310 Thermal Printer User Instructions AWT35 500729 IssueAA July 2011...

Page 2: ...nder license Full acknowledgment of the source must be given Avery Weigh Tronix is a registered trade mark of the Avery Weigh Tronix LLC This publication was correct at the time of going to print howe...

Page 3: ...right Notice and Disclaimer 7 EMC Caution 8 Chapter 2 Getting Started 9 Connections and EMC Precautions 9 Connector Details 9 Connector Pinouts 9 Connecting to a PC 10 Application Program 11 Chapter 3...

Page 4: ...4 ZG310 Thermal Printer User Instructions...

Page 5: ...ages Examples of special messages you will see in this manual are defined below The signal words have specific meanings to alert you to additional information or the relative level of hazard ELECTRICA...

Page 6: ...G310 is directly powered through the power jack at the rear of the printer The printer is designed for direct connection to a 12V or 24V vehicle battery Alternatively the user may make their own power...

Page 7: ...ht to modify and improve the firmware in its printer products at any time Every effort is made to ensure backward compatibility however no guarantee in this respect is given or implied The ZG310 inclu...

Page 8: ...Printer User Instructions 1 11 EMC Caution System EMC compliance remains the responsibility of the system designer It is recommended that screened cables are used earthing arrangements will depend on...

Page 9: ...cket Detail The maximum insertion length is 12 mm RJ12 Combined Data Socket Detail Power Supply Input Jack Socket Jack RJ12 Data Socket Pin Dimension mm Function Inner Inside 2 1 Positive 9 36 VDC Inp...

Page 10: ...match the printer 5a Your proposed application program may have a way of doing this or you can get to the DOS prompt eg C and type the following command line assuming you have connected the printer t...

Page 11: ...ng the printer from your application program As referred to in the Programmers Guide the ZG310 has a control code set based on the EPSON ESCPOS protocol Many of the commands are as closely compatible...

Page 12: ...print see below 3 2 Spool Mode In spool mode data is received and stored but not printed This is useful when printing needs to be suppressed during data transfer for example in mobile radio systems o...

Page 13: ...h this table may seem complicated few applications will produce many of the combinations Pattern Power Status Buffer Mode Constant Green OK Normal Fast Flashing Green OK Spool Long Green Short Red Low...

Page 14: ...new roll of paper 1 Slide the lid release button forwards until the lid springs open 2 Unwind a small amount of paper from the roll and insert the paper roll into the printer 3 Close lid and the pape...

Page 15: ...of an appropriate control code or after a programmable timeout delay 5 2 Spool Mode Spool mode can be entered by one of the following l a command from the host l a paper out condition or head up condi...

Page 16: ...1 and 12V a logical 0 with reference to the common ground The serial data output line TxD transmits XON XOFF and status information to the host at the same baud rate and in the same format as the seri...

Page 17: ......

Page 18: ...31 USA Tel 507 238 4461 Fax 507 238 4195 Email usinfo awtxglobal com www wtxweb com Avery Weigh Tronix UK Foundry Lane Smethwick West Midlands England B66 2LP Tel 44 0 8453 66 77 88 Fax 44 0 121 224 8...

Reviews: