20
Model 1040/XL User’s Manual
ING.TOL & DELAY
BAT.CNT
5.
Press
MENU
and
YES
is shown. Press
SELECT
key. . .
WAIT
is displayed while clearing, then
ALL
,
BATCH
, or
ACCUM
is
displayed.
6.
Press
GROSS
key. . .
Unit returns to
CLR.ACC
.
7.
Press the
GROSS
key to return to the gross weighing mode, or press
the
MENU
key to move to the next menu item.
The next menu item is
BAT.CNT
. This stands for Batch Counter. The
counter starts at 0 and increments each time a recipe is batched. This value
is cleared each time the batched data is cleared under CLR.ACC. This
counter goes up to 999999.
Follow these steps:
1.
From the Gross mode, press and hold the
MENU
key for two beeps (2
sec), then release. . .
LIST
is displayed.
2.
Press the
MENU
key repeatedly until. . .
bAT.CNT
is displayed.
3.
Press the
SELECT
key. . .
Current batch counter is shown.
4.
Press the
SELECT
key. . .
bAT.CNT is shown
5.
Press the
GROSS
key to return to the Gross weighing mode or press
the
MENU
key to move to the next menu item.
ING.TOL
stands for Ingredient Tolerance.
DELAY
stands for ingredient
advance Delay. These two parameters work together to make the Auto-
advance feature work. Set ingredient tolerance as a percentage (1-99) and
delay in seconds. See example below to help understand these items.
Example: Delay parameter is set to 20 seconds
Tolerance is set to 5%
When the ingredient weight being loaded falls within the tolerance
and stays within the tolerance for the time set in the delay
parameter, the indicator will auto-advance to the next ingredient.
If you undershoot the ingredient tolerance, you can advance the
ingredient manually by pressing the
MENU
key on the 1040. If
you overshoot, the display will alternate between
OVR.TOL
and
the amount overloaded until the indicator doesn’t sense motion,
then it will advance to the next ingredient.
Follow these steps to set or view the
ING.TOL
parameter: