41
4. POWER ON UTILITIES
There are six power-on utilities to set up and test printer hardware. These utilities are
activated by pressing FEED button and by turning on the printer power simultaneously.
The utilities are listed as below:
1. Gap/Black Mark sensor calibration
2. Gap/black mark sensor calibration, Self-test
3. Printer
initialization
4. Black mark sensor calibration
5. Gap sensor calibration
6. Skip
AUTO.BAS
4.1. Gap/Black Mark Sensor Calibration
Gap/black mark sensor sensitivity should be calibrated at the following conditions:
1. A brand new printer
2. Change label stock.
3. Printer initialization.
Please follow the steps below to calibrate the gap/black sensor
:
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3 Release the button when LED becomes
red
and blinking. (Any red will do during the
5 blinks).
It will calibrate the gap/black mark sensor sensitivity.
The LED color will be changed as following order
:
Amber
red (5 blinks)
amber (5 blinks) green (5 blinks)
green/amber (5 blinks) red/amber (5 blinks) solid green
It calibrates the sensor and measures the label length.
Summary of Contents for M09416 XLI
Page 33: ...M09416 XLI Thermal Direct Printer 30 3 2 Cover Drawing...
Page 35: ...M09416 XLI Thermal Direct Printer 32 3 4 Main Board Drawing...
Page 37: ...M09416 XLI Thermal Direct Printer 34 3 6 Top Inner Cover...
Page 39: ...M09416 XLI Thermal Direct Printer 36 3 8 Lower Inner Cover...
Page 41: ...M09416 XLI Thermal Direct Printer 38 3 10 Stepping Motor Fixing Assembly...
Page 43: ...M09416 XLI Thermal Direct Printer 40 3 12 Option Accessories Drawing...
Page 55: ......