 TRouBlEShooTING

 - Green indicator light - fast flashing .................. Searching to sync the Tx and Rx pair
 - Green indicator light - slow flashing ................ Idle - Tx and Rx are not synced or searching
 - Green indicator light - on continuous .............. Tx and Rx are synced together

If all connections are in place and still the system is not syncing, turn the Tx and Rx power off, wait 15 seconds, then turn both 
units on again. Also, refer to Step 2 and double check if the W-hDM3D-S-100 Scaler/Converter is outputting a mode that is 
compatible with your display monitor by pressing the mode button.

Summary of Contents for W-HDM3D-100-SET

Page 1: ...is publication and reserves the right to make changes to specifications and product descriptions at any time without notice No license whether express implied or otherwise to any intellectual property rights is granted by this publication Except as set forth in Avenview Standard Terms and Conditions of Sale Avenview assumes no liability whatsoever and disclaims any express or implied warranty rela...

Page 2: ...ep 2 Add the CW HDMDVI 100 Scaler Converter to the Transmitter 4 CW HDMDVI 100 Scaler Converter continued 5 Step 3 Connect the Receiver Unit Rx to a Destination 5 Step 4 Powering the Transmitter and Receiver Units 6 Optional Accessory CW HDMDVI 100 DC Splitter 6 An alternate power method for wireless RX or Tx units 6 Step 5 Sync and Begin Wireless Transmission 6 5 TROUBLESHOOTING 7 ...

Page 3: ...lay monitor A properly configured W HDM3D 100 transmitter receiver set forms a one to one bond with each other eliminating crosstalk with other wireless devices Up to six pairs of W HDM3D 100 transmitters receivers can be used simultaneously within the same room Each pair will operate at a different frequency within the 60Ghz band W HDM3D 100 is designed to be unaffected by cell phones RFID wirele...

Page 4: ...ter and W HDM3D R 100 receiver units 1 Wireless HD transmitter W HDM3D S 100 unit 2 Wireless HD receiver W HDM3D R 100 unit 3 User Guide 4 HDMI to DVI D cables 5 Medical grade power cord 6 Medical power adaptor 5V 2A For wall mounting 7 1x Bracket Standard type for installing and screw For monitor bezel installation 8 Bracket Medical type for installing and screw 9 DC splitter 10 DVI to HDMI signa...

Page 5: ...or the receiver The transmitter and receiver units can stand alone on a flat surface or use various brackets to mount onto other objects such as a display monitor It is recommended to verify that the wireless system is operating properly before mounting the Tx or Rx units permanently See the W HDM3D S 100 user guide for complete mounting instructions For best installation results The Tx and Rx sho...

Page 6: ... non standard video signals become wireless compatible Some medical device manufacturers prefer not to use the normal standardized video timings for HD image resolutions If this is the case with your intended video source then the W HDM3D S 100 system will be unable to successfully transmit a video signal In this situation the CW HDMDVI 100 scaler converter can be used to regulate the signal from ...

Page 7: ...g power and the HDMI signal from W HDM3D S 100 to the wireless Tx unit Connect a source s output to the DVI in port on W HDM3D S 100 Connect the power cord into an available electrical outlet and to the DC in port on W HDM3D S 100 As with the Rx and Tx units the DC Splitter accessory can be used to obtain power from an FSN medical display monitor Connect the W HDM3D S 100 Rx receiver to a destinat...

Page 8: ...have successfully paired and a signal should be transmitting To re sync a connection between Tx and Rx push and holding down the Pinhole Switch button for 4 5 seconds or until the LED flashes Be sure to select the appropriate DVI input mode on the destination display monitor There are times in the operating room when finding enough power outlets is an issue In order to minimize the amount of power...

Page 9: ...earching Green indicator light on continuous Tx and Rx are synced together If all connections are in place and still the system is not syncing turn the Tx and Rx power off wait 15 seconds then turn both units on again Also refer to Step 2 and double check if the W HDM3D S 100 Scaler Converter is outputting a mode that is compatible with your display monitor by pressing the mode button ...

Page 10: ...changes without further notice to a product or system described herein to improve reliability function or design With respect to Avenview products which this document relates Avenview disclaims all express or implied warranties regarding such products including but not limited to the implied warranties of merchantability fitness for a particular purpose and non infringement AV Connectivity Distrib...

Reviews: