background image

①  

Click the resolution drop-down box to select the working resolution.

②  

Binning can improve the sensitivity of the image. The larger the value is, the 

higher the sensitivity is.

③  

Observe the preview screen, and select the automatic or manual exposure 

setting according to the actual application requirements to obtain the desired 
image intensity.

 

Under industrial application, automatic exposure brightness can 

be adjusted via manual adjustment of exposure target value based on picture 

brightness; there's no exposure target value under the biological mode.

④  

Display and view the live preview frame rate.

⑤  

Depending on the application requirements, adjust the gain value to obtain the 

required image signal enhancement effect.

Default

White Balance

Red

Green

Blue

Lock WhiteBalance

CCT

Gray

128.0
128.0
128.0
2000K

3.4 Software Settings

1).

Basic Settings 

2).Image Adjustment 

①  

Under the biological mode, software defaults automatic white balance:

Conduct white balance calculation by moving samples under microscope to empty 
space, and then select [Lock White Balance] to complete white balance calibration 
operation;Under the industrial mode, by opening white balance options, regional 
white balance box will pop out on the preview pictures. Under stable lighting 

environment, move the regional white balance box to any white part of the pictures, 

then adjust size, and check [Lock White Balance] to lock present white balance, 
which will make white balance calibration more accurate.

②  

After selecting [Gray], the preview screen will turn into monochrome mode.

③  

Huerefers to the shade of the color, saturation is thepurity of the color, light is the 

brightness and darkness of the image, contrast is to adjust the difference of the 
brightness  of  the  image,  andsharpnessis  to  adjust  the  sharpness  of  the  image 
edges.

④  

When the preview shows a hazy effect, adjust [Permeability] to restore the clear 

picture.

When the light source is not uniform, or the preview image has dirty spots, use 

the [Flat Field Calibration Wizard] option to correct the image default background 
and obtain greater uniformity. 
Note: GT series cameras do not support CCT, Hue, Light.

  

When the preview image has dead pixels and color points, adjust [DPC] the dead 

pixel correction function to effectively remove the dead pixels to obtain a cleaner 
image. 

  

-10-

-9-

Default

Resolution

Exposure

 

Time

:

Auto

 

Exposure

Gain

:

0

2448x2048

Resolution

:

Exposure Control

36

.

7fps

0

25

34

OK

s

ms

μ

s

Binning

1x1

2x2

3x3

4x4

Target:

128

Image

 

Adjust

Hue

Saturation

Light

Contrast

180
64
64
33

Permeability

16

Flat

 

Field

 

Calibration

 

Wizard

DPC

0

Real-time dynamic adjustment

Default

Sharpness

0

Summary of Contents for 26100-258

Page 1: ...Mighty Cam Pro User Guide Item 26100 258 Tools for Innovation AVEN Advancing aventools com Aven Inc 4330 Varsity Drive Ann Arbor MI 48108 Phone 734 973 0099 Email info aventools com Web aventools com...

Page 2: ...USB3 0 data cable 2 x 1 x Camera 1 x Software U disk Screws 20MP Resolution Cooling noise reduction Real time 3D noise reduction Real time sharpening Real time stitching Real time EDF USB3 0 1 x Came...

Page 3: ...dapter Note itemsareonlyavailablewhenthecameraispurchasedwiththescreen 2 Camera Interface Description 2 1 FL Cooled Camera USB3 0 2pcs Indicator lights Screw positioning hole Powerswitch USB3 0 Poweri...

Page 4: ...or off to turn on or off the HDMI camera 5 SD card To get faster and more stable data transfer we recommend you to use a Class10 SD card Connect Or Power supply Note Some cameras support USB power su...

Page 5: ...computer It is recommended that you close all other applications before continuing Click Next to cuntinue or Cancel to exit Setup Next Cancel Go to the Device Manager and check whether the driver is i...

Page 6: ...t on the preview pictures Under stable lighting environment move the regional white balance box to any white part of the pictures then adjust size and check Lock White Balance to lock present white ba...

Page 7: ...Use File Name A file will be saved with the name TS as default but the name can be customized Customized name time stamp is supported A name can contain up to 64 bytes File format Support JPG TIF PNG...

Page 8: ...the cursor is moved to the left of the screen Capture and Setting icons will appear Click Setting to get the parameter setting menu Calibration Horizontalflip Verticalflip Zoomin Mask Album Compare Ba...

Page 9: ...ctable to have the data of perimeter or area 8 Perpendicular Measure the perpendicular length 9 Concentric circles Get the diameters of the two concentric circles 10 Bicircle Get the distance between...

Page 10: ...ace 6 Use only the original power adapter Ensure the adapter and associated cables are free from items that may cause damage If the power adapter is damaged please contact the supplier for an immediat...

Reviews: