4.7
Vary standard speed („Pitch“)
Each of the standard speeds can be varied with a resolution of 0.01 rpm.
There are no restrictions regarding the setting value: The speed can be set
from the minimum to the maximum possible speed of the motor.
►
Press keys [33 45] (repeatedly) to select the desired speed of the
platter.
The motor starts and accelerates to nominal speed.
►
Press [+] to increase speed.
►
Press [-] to decrease speed.
Short pressing changes the speed by 0.01 rpm. Longer pressing changes
the speed continuously, whereby the step size of the speed change
increases by the duration of the key operation.
The maximum step size of the change can be set individually in the confi-
guration menu under menu item „Key Delay“.
The display shows the target speed. As long as the display is flashing, the
drive unit is in the dynamic phase and the selected speed has not yet been
achieved.
A pitch setting will not be stored!
A varied speed setting is retained only until key [33 45] is
pressed again or the device is switched off with key [On Off].
4.8 Operating time alerts
In order to ensure optimum playback quality and to protect your valuable
vinyl discs, the drive belt and pickup should be replaced after a certain
period of operation.
We have therefore integrated separate hour meters for drive belt and
pickup into these drive units.
The number of hours until a operating time alert for component replace-
ment appears on the display can be set individually in the Configuration
menu (
➔
5.5).
When the maximum operating time of the drive belt and/or the pickup has
been reached, the corresponding warning notes are shown, alternating
with the display of „
0
“, indicating that the adjusted maximum operating
time of a component has been achieved.
Max. operating time drive belt achieved
Max. operating time pickup achieved
Max. operating time drive belt and pickup achieved