Avaya X330W-2USP Quick Start Manual Download Page 6

5

Configure the Module

L

Before you can set up the X330W-2USP module you must power on and set up the 
Avaya P330 stack as described in the Avaya P330 User’s Guide.

L

You can configure the X330W-2USP module either via its console port or by opening a 
session to the module from the P330 switch in which the module is installed using the 

session wan

 command.

Avaya CLI Hints and Tips

CLI Command Conventions

CLI commands for you to enter are in the 

computer bold

 

font.

Information displayed on screen as well as parameters of a command are displayed in 

computer

 font.

Parameters that you enter are in pointed brackets <>.

Alternative but mandatory keywords are grouped in braces {} and separated by a vertical bar 
|.

Optional keywords are in square brackets [ ] and options are separated by a vertical bar |.

If you enter an alphanumeric string of two words or more, enclose the string in quotes.

The Avaya CLI has several features which improve ease of use:

To display all commands available in a context type a question mark.

To display all commands starting with a certain string, type the first few letters followed by a 
question mark.

To get help containing all commands parameters with their legal values as well as its syntax 
and an example, type a question mark at the end of command or at the stage where it is 
unique.

Use the Tab key to complete an unambiguous command.

The following steps describe how to configure the X330W-2USP module using the Avaya CLI.

Establishing a Console (Serial) Connection

Perform the following steps to connect a terminal to the Console port of the X330W-2USP for 
configuration of WAN parameters using the CLI:
1

Use the supplied serial cable to attach the RJ-45 console connector to the Console port. 
Connect the DB-9 connector to the serial (COM) port on your PC/terminal.

2

Use the following serial port settings on the PC: 9600 baud, 8 bits, 1 stop bit and no parity. If 
you connected a PC, run a VT-100 emulation session. (You can use the Windows® 
HyperTerminal.)

L

The terminal connected to the serial port must be configured with the same settings; this 
setting will work with any PC COM port over a DB9 to RJ45 connector.

3

Press the Enter key.

Summary of Contents for X330W-2USP

Page 1: ...ule Unpack the Module Important Safety Information Note You should upgrade the P330 switch firmware and Embedded Web Manager to version 3 12 or higher before installing the X330W 2USP module If you ne...

Page 2: ...on To avoid damage from static only hold the WAN Expansion Router Module by the edges Do not touch the top or bottom of the circuit board If possible wear a wrist strap and use an anti static bag Caut...

Page 3: ...Documentation Avaya X330W 2USP WAN Access Router Modules Quick Start Guide this document Avaya X330W 2USP WAN Access Router Modules Release Notes Avaya X330WAN Documentation and Utilities CD Avaya War...

Page 4: ...igned with the guide rails L The PCB fits into the guide rails and not the metal base plate 3 Press in the expansion module firmly until it is completely inserted into the Avaya P330 switch 4 Gently t...

Page 5: ...tEthernet port to a PC or workstation you should use a crossed cable L If you are connecting the FastEthernet port to another switch you should use a straight cable Connecting the Console Port Each Av...

Page 6: ...a context type a question mark To display all commands starting with a certain string type the first few letters followed by a question mark To get help containing all commands parameters with their l...

Page 7: ...onnect via its console interface to the X330W 2USP L The console interface configured with the interface Console command must be on a different subnet from the router interfaces 6 Use the following co...

Page 8: ...that the running state is idle by entering the show copy status command 6 Reset the switch using the reset command Configuring FastEthernet Interfaces L All CLI commands mentioned in this section are...

Page 9: ...IP addresses 10 10 10 1 on VLAN 2 and 20 20 20 1 and 30 30 30 1 on VLAN 3 perform the following X330WAN 2USP 1 super interface FabricFastEthernet 1 2 X330WAN 2USP 1 super if FabricFastEthernet1 2 ip a...

Page 10: ...rame Relay L The default value for Frame Relay lmi type is auto learning supporting both Annex A Q933 and Annex D ANSI 7 Type exit to return to Supervisor mode 8 Use the interface serial if number if...

Page 11: ...2USP you chose If there is no response check the IP address and default gateway of both the X330W 2USP and the station 3 From the Microsoft Windows taskbar of your PC click Start and then Run or from...

Page 12: ...lt parameters we recommend that you use the CLI Please refer to the Avaya X330WAN User s Guide Function Default Setting Port speed FastEthernet 100 Mbps Port duplex FastEthernet Full Duplex Auto negot...

Page 13: ...ent interface pmi to the X330W 2USP module The default pmi is the first interface you define 1 Verify that there is communication between the Master Switch and the X330W 2USP using the ping command to...

Page 14: ...indows Explorer 4 Open the embweb aux files folder on the CD 5 Double click on the plugin_a_b_c exe file a b and c are the version numbers of the plug in 6 Follow the on screen instructions Or install...

Page 15: ...L Documentation and Online Help Refer to the Avaya X330WAN Documentation and Utilities CD for full instructions...

Page 16: ...756 800 Sweden 46 851 992 080 Czech Rep 31 70 414 8006 Luxemburg 352 29 6969 5624 Switzerland 41 22 827 8741 Denmark 45 8233 2807 Macedonia 31 70 414 8041 Tanzania 31 70 414 8060 Egypt 31 70 414 8008...

Reviews: