5
Changing the Primary Management Interface (pmi)
L
The default pmi is the first interface you define.
To change the pmi:
1
Enter one of the interface contexts as explained before.
2
If there is no ip assigned on that interface use the
ip address
<ip_addr>< net-mask>
command.
3
Use the
ip routing-mode rt_primary_mgmt
command to set the interface as pmi.
X
The following message is displayed
4
Enter the
copy running-config startup-config
command.
5
Check that the running state is “idle” by entering the
show copy status
command
6
Reset the switch using the
reset
command
.
Establishing a Telnet Connection
Perform the following steps to establish a Telnet connection to the X330W-2USP for
configuration of WAN parameters. Telnet directly to one of the Router IP addresses:
1
Connect your station to the network.
2
Verify that you can communicate with the X330W-2USP using the ping command to the IP
address of the X330W-2USP you chose. If there is no response, check the IP address and
default gateway of both the X330W-2USP and the station.
3
From the Microsoft Windows® taskbar of your PC, click Start and then Run (or from the
DOS prompt of your PC), then start the Telnet session by typing:
telnet
<X330WAN_IP_address>
. For example:
telnet 149.49.32.134
.
L
You can also Telnet the IP address of the P330 stack. If you Telnet the IP address of the
stack, a connection is established with the Switch CLI entity of the Master module of the
stack. If you want to connect to the X330W-2USP CLI entity, use the
session
[<mod_num> [wan]]
command. If the IP address in the Telnet command is the
address of the X330W-2USP router, connection is established to the X330W-2USP CLI
entity.
4
When prompted for a Login Name, enter the default name
root
.
5
When prompted for a password, enter the User Level password
root
in lower case letters.
L
Do NOT use uppercase letters.
X
You can now configure the X330W-2USP.
The primary management interface has changed. For this change to
take effect, you need to copy running-config startup-config and
then reset the device.