Avaya VSP 4000GSX Series Installation Job Aid Download Page 6

Installing SFP transceivers

Install SFP transceivers by performing this procedure.

1. Remove the transceiver from the protective packaging.

2. Verify that the transceiver is the correct model for the network configuration.

3. Grasp the transceiver between your thumb and forefinger.

4. Insert the transceiver into the proper module on the switch. Apply a light pressure to the

transceiver until it clicks and locks into position in the module.

5. Remove the dust cover from the transceiver optical bores.

Removing SFP transceivers

Remove SFP transceivers by performing this procedure.

1. Disconnect the network fiber cable from the transceiver.

2. Use the locking mechanism on the transceiver to release it. The locking mechanism varies

from model to model as illustrated below.

3. Slide the transceiver from the module slot.

4. If the transceiver does not slide easily from the module slot, use a gentle side-to-side rocking

motion while firmly pulling the transceiver from the slot.

5. Attach a dust cover over the fiber-optic bores and store the transceiver in a safe place until

you need it.

Important:

Discard transceivers in accordance with the proper laws and regulations.

Power specifications for the Avaya VSP 4450GSX series switches

This section describes the regulatory AC and DC power specifications for the Avaya VSP 4000
4450GSX series switches.

The following table describes the regulatory AC power specifications for the VSP 4450GSX-PWR+
switch and its TAA compliant version. The regulatory AC power specifications are based on the
maximum rated capacity of the power supplies and are not based on typical power consumption,
which is lower.

July 2015

Installation Job Aid for Avaya VSP 4000 4450GSX series     

6

Summary of Contents for VSP 4000GSX Series

Page 1: ...or or reseller Notices Notice paragraphs alert you about issues that require your attention The following paragraphs describe the types of notices used in this guide Note Notes provide tips and useful...

Page 2: ...dio interference in which case the user may be required to take appropriate measures Caution When mounting this device in a rack do not stack units directly on top of one another in the rack Each unit...

Page 3: ...upply At least 2 inches 5 08 cm on all sides of the switch unit for ventilation Adequate space at the front and rear of the switch for access to cables If you are installing a single VSP 4000 switch o...

Page 4: ...le or shelf as illustrated below Allow at least 2 inches 5 1 centimeters on each side for proper ventilation and at least 5 inches 12 7 centimeters at the back for power cord clearance Installing the...

Page 5: ...ced if necessary The rack is grounded to the same grounding electrode used by the power service in the area The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to t...

Page 6: ...ustrated below 3 Slide the transceiver from the module slot 4 If the transceiver does not slide easily from the module slot use a gentle side to side rocking motion while firmly pulling the transceive...

Page 7: ...hich is lower Table 2 DC power specifications 4450GSX DC Input Current 25A Input Voltage 12VDC Power Consumption Typical 116W Maximum 164 6W Thermal Rating 508 BTU Hr Power supply power specifications...

Page 8: ...W on 12 ports 835W with one power supply 1835W with two power supplies 17 8W or 32 4W 802 3 at 1 power supply The VSP 4450GSX PWR can support 802 3af 17 8W or 32 4W on each port with one power supply...

Page 9: ...ceable power supplies 1 If a blanking plate covers the required power supply slot remove the blanking plate before attempting to insert the power supply 2 Insert each power supply into a rear power su...

Page 10: ...5P male plug UL recognized UL stamped on cord jacket CSA certified CSA label secured to the cord 100 or 120VAC 50 60 Hz Single phase United Kingdom BS1363 male plug with fuse Harmonized cord 240VAC 50...

Page 11: ...Figure 3 DC power cable Figure 4 DC power cord housing unit with terminals July 2015 Installation Job Aid for Avaya VSP 4000 4450GSX series 11...

Reviews: