Connecting to AC power
To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
Table 5: International power cord specifications
Country and Plug Specification
Specifications
Typical Plug
Continental Europe:
• CEE7 standard VII male plug
• Harmonized cord (HAR marking on the outside of the cord
jacket to comply with the CENELEC Harmonized
Document HD-21)
• 220 or 230VAC
• 50 Hz
• Single phase
United States of America, Canada, and Japan:
• NEMA5-15P male plug
• UL-recognized (UL stamped on cord jacket)
• CSA-certified (CSA label secured to the cord)
• 100 or 120VAC
• 50–60 Hz
• Single phase
United Kingdom:
• BS1363 male plug with fuse
• Harmonized cord
• 240VAC
• 50 Hz
• Single phase
Australia:
• AS3112-1981 male plug
• 240VAC
• 50 Hz
• Single phase
Danger:
Using power cords with a proper grounding path
Use only power cords that have a grounding path. Without a proper ground, a person who
touches the switch is in danger of receiving an electrical shock. Lack of a grounding path to the
switch can result in excessive emissions.
Connecting to DC power
To connect DC power to the switch, use the short power cable that is provided with the switch.
July 2015
Installation Job Aid for Avaya VSP 4000 4450GSX series
10