Preparing for Installation
Environmental requirements - Page 15
Environmental requirements
The planned location must meet the following requirements:
– Check that the area is a well ventilated area, having a temperature range of 0
°
C to
+40
°
C and a humidity range of 10% to 95% non-condensing.
– Check there are no flammable materials in the area.
– Check there is no possibility of flooding.
– Check that no other machinery or equipment needs to be moved first.
– Check that it is not an excessively dusty atmosphere.
– Check that the area is unlikely to suffer rapid changes in temperature and humidity.
– Check for the proximity of strong magnetic fields, sources of radio frequency and other
electrical interference.
– Check there are no corrosive chemicals or gasses.
– Check there is no excessive vibration or potential of excessive vibration, especially of
the cabinet mounting surface.
–
Check that, for the USA only, where telephones are installed in another building, that
the appropriate IROB protectors are fitted (see page
).
IMPORTANT SAFETY INSTRUCTIONS
When using your telephone equipment, basic safety precautions should always be
followed to reduce the risk of fire, electric shock and injury to persons, including the
following:
1. Do not use this product near water, for example, near a bath tub, wash bowl, kitchen
sink or laundry tub, in a wet basement or near a swimming pool.
2. Avoid using a telephone (other than a cordless type) during an electrical storm. There
may be a remote risk of electric shock from lightning.
3. Do not use the telephone to report a gas leak in the vicinity of the leak.
4. Use only the power cord and batteries indicated in this manual. Do not dispose of
batteries in a fire. They may explode. Check with local codes for possible special
disposal instructions.
SAVE THESE INSTRUCTIONS.
Power Supply Requirements
Avaya IP Office - Small Office Edition should only be connected to a clean power supply
or to a UPS with 3-pin connectors including earth.
CAUTION:
The Lump-in-Line PSUs supplied with each Avaya IP Office - Small Office
Edition module must only be connected to a 50/60Hz, 100-240V power
source.
–
UPS Equipment :
The use of UPSs to support the Avaya IP Office - Small Office Edition system during
mains power failure is highly recommended. Such equipment also provides mains
conditioning. Contact Avaya for details of preferred and tested suppliers and models.